Reference Guide

getsvctag
Description
Displays the Service Tag of the host system.
Synopsis
racadm getsvctag
Input
getsvctag
Output
Y76TP0G
Example
racadm getsvctag
getsysinfo
Description
Displays information related to iDRAC, CMC, managed system, and watchdog configuration.
NOTE: The local racadm getsysinfo subcommand on Linux displays the Prefix Length on
separate lines for IPv6 Address 2 — IPv6 Address 15 and the Link Local Address.
NOTE: The host name and OS Name fields in the getsysinfo output display accurate information
only if the Dell OpenManage Server Administrator is installed on the managed system. Else,
these fields may be blank or inaccurate. An exception to this are VMware operating system
names, which are displayed even if the Server Administrator is not installed on the managed
system.
Synopsis
racadm getsysinfo [-d] [-s] [-w] [-A] [-c] [-4] [-6]
Input
—4 — Displays IPv4 settings
—6 — Displays IPv6 settings
—c — Displays common settings
—d — Displays iDRAC or CMC information
—s — Displays system information
—w — Displays watchdog information
—A — Eliminates the printing of headers/labels
NOTE:
If the —w option is not specified, then the other options are used as defaults.
—s and —w options are not valid on the M1000e systems.
Output
racadm getsysinfo
RAC Information:
RAC Date/Time = Tue May 14 14:04:59 2013
Firmware Version = 1.40.40
Firmware Build = 13
Last Firmware Update = 05/10/2013 20:56:10
Hardware Version = 0.01
MAC Address = 90:B1:1C:11:3C:B7
Common settings:
Register DNS RAC Name = 0
DNS RAC Name = idrac-H1VGF2S
82