setarraycfg
Description This command is applicable only for CMC. To configure storage array properties, run
this command.
Synopsis
racadm setarraycfg -m module –n <member_name> <member_ip>
<member_mask> <member_gateway> -e 0|1 -g <groupname>
<group_id> <group_password> [<admin_password>] [-f A|B]
racadm setarraycfg -f A|B
NOTE: The valid value for -m is server–n, where n=1–16.
Input
-m — Module is one of the following values:
server–n: where n = 1–7 and 9–15
<member_name> — A unique and descriptive name that is fewer than 64
alphanumeric characters, without spaces. The first character is a letter or a
number. It is used only to identify and administer the array.
<member_ip> — Each member IP Network address must have at least one
network interface on the same subnet as the group IP address.
<member_mask> — Member Netmask combines with the member IP address to
identify the subnet on which the network interface specified resides. The default is
255.255.255.0
<member_gateway> — Member Gateway network address is for the device
that connects the subnet and forward the network traffic beyond the local network.
—e — Selects existing or create new group for a member. The valid values are:
0 — to create new group
1 — to use existing group
NOTE: If —e is 0, then admin password is mandatory.
<groupName> — Name of the group for administrative purpose. You can use up
to 64 alphanumeric characters and hyphens. The first character must be a letter or
number.
<group_ip> — Group IP and Network address for the group. The group IP
address is used for administrative and host access to volumes.
<group_password> — Group Membership Management Password is required
when adding members to the group. The password must have 3 to 16 alphanumeric
characters and is case-sensitive.
<admin_password> — Group Administration Password to set admin password
when creating new group and overrides the factory-set password.
grpadmin
is the
default
grpadmin
account. The password must have 3 to 16 alphanumeric
characters and is case-sensitive.
—f — The valid values are
A or B
. Select Fabric used for data I/O. Options are:
Fabric A (LOM port)
Fabric B (Mezz port)
The default is Fabric B. If the option is not specified, then the configuration is not
done.
Output <module> configuration was initiated successfully. It may take several minutes to
complete.