Release Notes

What’s New
Support for the following:
o
PowerEdge R920 and R220 servers
o
PowerEdge FX2/FX2s chassis
o
PowerEdge FM120x4, FC620, and FC420 servers
o
Emulex cards:
Emulex OneConnect OCm14104-UX-D 4-port 10GbE rNDC CNA
Emulex OneConnect OCm14102-U2-D 2-port 10GbE bNDC CNA
Emulex OneConnect OCe14102-UX-D 2-port PCIe 10GbE CNA
Emulex OneConnect OCm14102-U3-D 2-port 10GbE Mezz CNA
o
NVMe SSD
o
NVIDIA GRID K2 Active GPU card
o
New memory
o
Internet Explorer Version 11
o
Red Hat Enterprise Linux version 6.5 and ESX 5.1 U2
* New system ID for PowerEdge M820 in Dell PowerEdge VRTX chassis
iDRAC7 Fixes
When Virtual Console port number changed through RACADM command, few unrelated text
may appear in the same console.
iDRAC not ready.
iDRAC7 - Important Notes
After an iDRAC7 firmware update, a few of the iDRAC7 Web interface panels or navigation menu
items may contain incorrect or invalid entries. To resolve this, clear the browser cache(s) after
updating the iDRAC7 firmware.
License Requirements:
Software licensing has replaced hardware licensing. For more information, see, the
Dell License
Manager User's Guide
.
Lifecycle Controller features such as Auto Discovery and vFlash are now licensed. Install the correct
licenses for Lifecycle Controller Remote Services to work properly.
Only if there is one or more network interface cards (NDC or LOM) present on the managed
system,
Network Devices
appears under
Overview
->
Hardware
section in the iDRAC7 Web
interface.
When using iDRAC7 Web interface in Firefox 3.6 if the SD card is removed while partition
creation is in-progress, "The operation has been completed successfully" message is displayed.
For the Virtual Console and Virtual Media to function properly, iDRAC7 Web URL must be added
to the Local Intranet site list and the security level for the Local Intranet zone should be set to
Medium-Low. In addition, if Virtual Console and Virtual Media are configured to use Java plug-in,
then disable the
Enhanced Security Mode
in Internet Explorer. If this is not possible, then in
iDRAC7, configure Virtual Console to use the ActiveX plug-in.
If the instant messenger is launched in the Virtual Console viewer with ActiveX native plug-in
and another application is started (example Notepad, WordPad, and so on) without minimizing
the Virtual Console, the instant messenger box also pops-up on other applications. This does
not happen with Java plug-in.
When a system is in POST, it is not possible to attach a vFlash partition as the first boot device.
Virtual Console Viewer from iDRAC7 Web interface terminates when the managed system is
restarted.