Release Notes

Issue 77:
Description
The state of the PCIe SSD connected to the server is not reflected correctly or takes several minutes to
reflect the correct state.
Resolution
Power cycle the server or re-insert the PCIe SSD reflecting the incorrect state.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PCIe SSDs (that is, NNMe devices).
Issue 78:
Description
If the system is powered on and if the server chassis lid is open for any reason, the following System
Event Log (SEL) message may be generated:
SEC0033: "The chassis is open while the power is off.
Resolution
If the system is still powered on, ignore this message.
Versions/Systems Affected
All 12th generation Dell PowerEdge Rack and Tower servers.
Issue 79:
Description
If the iDRAC has a large number of records in the Lifecycle Log and from remote RACADM, if you run the
racadm lclog view, an error message is displayed.
Resolution
To view the logs, use local racadm, firmware racadm, iDRAC Web interface or WSMAN. To view the latest
logs using remote racadm, use the
-n option. For example, to view the 10 latest logs, use racadm lclog
view -n 10
.
Versions/Systems Affected
All 12th generation Dell PowerEdge systems with iDRAC7.
Issue 80:
Description:
If the license level is Base Management with IPMI, when you upload a Dell Update Package (DUP) in .exe
format, a license related error message appears.
Resolution
In Base Management with IPMI license, you can only upload .d7 image format. To upload .exe files,
upgrade the license to iDRAC Enterprise and then retry the operation.
Versions/Systems Affected
All 12th generation Dell PowerEdge systems with iDRAC7.