Release Notes

Issue 22
Description
When virtual world wide name and virtual world wide port name attributes on a NIC partition are set using the WS-MAN
interface, the new values are not updated in the iDRAC7 Web interface or when racadm getsysinfo is run.
Resolution
Use WS-MAN interface to obtain the updated values for those attributes.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 23
Description
The Predicted Capacity Status attribute of the storage controller battery reported by iDRAC7 interfaces (example, iDRAC7
Web interface, RACADM and so on) is deprecated and will be removed in a future release. It may not report the accurate
value under some scenarios.
Resolution
To view the correct battery state, use the storage battery state/status values instead.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 24
Description
When inventory changes are done to the storage sub-system (such as inserting and removing disk drives, and so on) before
or during POST/reboot, the corresponding events may not be recorded in Lifecycle log. SNMP traps/email alerts may not be
generated and the inventory changes may not be correctly reflected in the iDRAC7 interfaces (example, iDRAC7 Web
interface, RACADM and so on).
Resolution
To view the correct storage inventory data, perform a server power cycle (cold boot).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 25
Description
If a NIC card, with partitioning enabled, is replaced with a similar type of card, without partitioning enabled, the
configurations from the previous card are not applied to the new card.
Resolution
After the previous card is replaced with a new card and the system is powered on, go to Option
ROM (CTRL-R)
and enable