Reference Guide

NOTE: For CMC, these commands specifically apply to an active-CMC update.
The following table describes the firmware update method supported for each interface.
FW Update Method iDRAC on Blade Servers iDRAC on Rack and Tower
Servers
CMC
Local RACADM
Yes Yes No
Local RACADM - TFTP
Yes Yes No
Local RACADM - FTP
Yes Yes No
Remote RACADM
Yes Yes Yes
Remote RACADM-TFTP
Yes Yes Yes
Remote RACADM-FTP
Yes Yes Yes
Firmware RACADM-TFTP
Yes Yes Yes
Firmware RACADM-FTP
Yes Yes Yes
get
Description
You can read the value of configuration objects on the iDRAC and display RAC object
values. The displayed values are currently used by the device. If the values are
pending, then commit and reboot job should be created using the jobqueue command.
For more information, see jobqueue.
This subcommand is applicable for iDRAC only.
Synopsis
racadm get -f <filename>
racadm get <FQDD
Alias>.<index>.<group>.<index>.<object>
racadm get <FQDD Alias>.<group>
racadm get <FQDD Alias>.<group>.<object>
racadm get <FQDD Alias>.<group>.<index>.<object>
racadm get -f <filename> -t <filetype> -u <username>
-p <password> -l <CIFS share>
Input
<FQDD Alias> -
Examples for FQDDs
* System.Power
* System.Power.Supply
* System.Location
* LifecycleController.LCAttributes
* System.LCD
* iDRAC.Serial
For the list of supported groups and objects under the get command, see Database
Objects With Get and Set Commands
<group> — Specifies the group containing the object that is to be read.
60