Reference Guide

System.Power.Cap.Btuhr (Read or Write)
Description Represents the maximum power in BTU/Hr a device is
allowed to consume. The device may throttle in order to
meet this capacity.
NOTE: This value is read only on Modular servers .
NOTE: This value is applicable only if
System.Power.Cap.Enable is set to 1.
Legal Values Values from 1 - 65535
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency System.Power.Cap.Enable has to be enabled.
System.Power.Cap.Enable (Read or Write)
Description Enables or disables user specified power budget threshold configuration.
NOTE: This value is read only on Modular servers because CMC controls
the capping.
Legal Values
0 - Disable
1 - Enable
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Cap.MaxThreshold (Read Only)
Description This is the maximum server power capacity. This is based on the current component
inventory.
Legal Values Values from 1 - 65535
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Cap.MinThreshold (Read Only)
Description
This is the lowest calculated power consumption of the device. This is based on
the current component inventory.
Legal Values Values from 1 - 65535
Write Privilege Configure iDRAC
252