Reference Guide

-s — Power state of the host when the import operation completes. The parameters are
"On" for powered ON and "Off" for powered OFF. If this parameter is not specified, power
ON is taken as default.
Output
Object value modified successfully
Failure message indicating reason for failure.
Example
Configure the iDRAC using a file:
$ racadm set -f myrac.cfg
Configure LCD String:
$ racadm set system.lcd.LCDUserString test
Object value modified successfully
Configure rack name for server:
$ racadm set system.location.rack.name rack1
Configure a RAC from an XML configuration file located on a remote CIFS share:
$ racadm set -f myfile.xml -t xml -u myuser -p mypass -
l //10.1.2.3/myshare
Configure a RAC from an XML configuration file located on a remote NFS share:
$ racadm set -f myfile.xml -t xml -l 10.1.2.3:/myshare
Configure a RAC from an XML file, with a wait time of ten minutes, shutdown type
graceful and end host type power on:
$ racadm set -f myfile.xml -t xml -b "graceful" -w 600 -s
"on"
setarraycfg
Description This command is applicable only for CMC. Use this command to configure storage
array properties.
Synopsis
racadm setarraycfg -m module –n <member_name> <member_ip>
<member_mask> <member_gateway> -e 0|1 -g <groupname>
<group_id> <group_password> [<admin_password>] [-f A|B]
racadm setarraycfg -f <A|B>
NOTE: The valid value for -m is server-n, where n = 1 to 16.
Input
-m — Module is one of the following values:
server-n: where n = 1 to 7 and 9 to 15
<member_name> — A unique and descriptive name that is fewer than 64
alphanumeric characters, without spaces, and the first character is a letter or
a number. It is used only to identify and administer the array.
<member_ip> — Each member IP Network address should have at least one
network interface on the same subnet as the group IP address.
<member_mask> — Member Netmask combines with the member Ip
address to identify the subnet on which the network interface specified
resides. The default is 255.255.255.0
<member_gateway> — Member Gateway network address is for the
device that connects the subnet and forward the network traffic beyond the
local network.
118