Release Notes

Important notes
1. When firmimg.d7 update from HTTPs share using firmware RACADM update is performed, it displays an additional error message
RAC989 intermittently, along with the completion message RAC987. During this update, the proxy is enabled. When this error is
displayed, a corresponding job state shall be monitored using any of the iDRAC interfaces (RACADM/GUI/WSMAN) to check the
update status.
2. When firmimg.d7 update using local RACADM interface is performed, it exits without displaying any status message. When this
happens, a corresponding job state shall be monitored using any of the iDRAC interfaces (RACADM/GUI/WSMAN) to check the
update status.
3. Firmware update from version 2.63.60.62 to version 2.65.65.65 from remote network share using remote RACADM interface may
throw an error message - "Error: Session is Invalid". When this error is displayed, a corresponding job state shall be monitored using
any of the iDRAC interfaces (RACADM/GUI/WSMAN) to check the update status. With version 2.65.65.65, RAC987 EEMI is
displayed instead of "Error: Session is Invalid".
4. The drivers that are exposed by LC are present in a read-only drive that is labeled OEMDRV and the drive is active for 18 hours. During
this period:
You cannot install any DUPs.
LC cannot invoke CSIOR.
However, if an AC power cycle (cold boot) is performed, the OEMDRV drive is automatically deleted.
5. CPLD firmware update has no impact on Trusted Platform Module enablement.
6. Depending on the virtual storage device attached through iDRAC, that is, USB drive or CD/DVD .ISO file, LC displays Virtual Floppy
or Virtual CD respectively.
7. If Test Network Connection fails for a valid address, try configuring the network settings again. If the issue persists, restart the system
and retry the operation.
8. When you reset or update the iDRAC, you must reboot LC if it is launched already. If you fail to reboot, LC may behave unexpectedly.
9. On PowerEdge FC630, PowerEdge FC830, and PowerEdge FC430 systems, part replacement is not supported if a single PERC
(FS332) is replaced with a dual PERC (FD332) or vice versa.
10. After performing a firmware update or rollback operations from LC, the host is rebooted by default. Reboot the host server again to
display the updated firmware versions in the View Current Versions wizard.
11. When you update a 12th generation PowerEdge server backplane-expander firmware for PowerEdge R920 firmware to version 0.33 or
2.03, the comparison page displays only one expander entry. However, firmware for both the expanders is updated.
12. Fibre channel NIC cards with two or four ports are displayed as a single port card in Lifecycle Controller. However, all ports are
updated when a firmware update is performed.
13. The option to enable or disable the disk cache policy for SWRAID controllers is supported only on SWRAID controller driver version
4.1.0-0025 or later.
14. ResetKeys under Action in the SecureBoot resource is available only on systems with supported BIOS.
15. The SecureBoot navigation link is available under Computer System only if the SecureBoot feature is supported by the BIOS installed
on the system.
16. Rollback is not supported for CPLD.
17. The certificate warning message that is displayed during an HTTPS transaction is due to the server presenting a certificate issued by
an entity that is not trusted by the system, or certificate that is presented by the server is expired.
6
10 Important notes