Release Notes
Table Of Contents
- iDRAC8/7 with Lifecycle Controller Version 2.60.60.60 Release Notes
- Overview
- Platforms affected
- What is supported
- New in this release
- Fixes
- Important notes
- Limitations
- Known Issues — To be fixed in future releases
- Installation
- Lifecycle Controller Remote Services — client tools
- Accessing documents from Dell Support site
- Contacting Dell EMC
• VLAN Conguration is not supported on all vendor FC cards and the following Emulex cards.
– Emulex OneConnect OCe14102-U1-D 2-port PCle 10GbE CNA
– Emulex OneConnect OCm14104-U1-D 4-port 10GbE rNDC CNA
– Emulex OneConnect OCm14102-U5-D 2-port 10GbE Mezz CNA
– Emulex OneConnect OCm14102-U4-D 2-port 10GbE bNDC CNA
– Emulex OneConnect OCe14102-N1-D 2-port PCle 10GbE NIC
– Emulex OneConnect OCm14104-N1-D 4-port 10GbE rNDC CNA
– Emulex OneConnect OCm14102-N5-D 2-port 10GbE Mezz CNA
– Emulex OneConnect OCm14102-N6-D 2-port 10GbE bNDC CNA
• LC displays two or more drive names for some CDs or DVDs, such as the ones containing operating systems.
• Network operations such as Update, Export, or Import may take more time than expected. The delay may occur because the source or
destination share is not reachable or does not exist, or due to other network issues.
• If the operating system (OS) selected for installation and the OS on the media used are dierent, LC displays a warning message.
However, while installing Windows OS, the warning message appears only when the bit count (x86 or x64) of the OS does not match.
For example, if Windows Server 2008 x64 is selected for installation and Windows Server 2008 x86 media is used, the warning is
displayed.
• LC does not support OS deployment on Dell Precision Workstation R7920.
• When NPAR is enabled, the port numbers displayed on the LC Network Settings page (Settings > Network Settings) do not match
the port numbers displayed on the Device Settings page (System Setup > Advanced Hardware Conguration > Device Settings).
• Lifecycle Controller supports OS deployment on bootable devices (systems without a RAID controller) in the BIOS mode only.
• In the Spanish help page, the word encrypted is incorrectly translated as scripted in Step 3 OS deployment.
• Operating system installation might fail if the server has only PCle NVMe SSD drives and if you have selected BIOS as boot mode. If
server has both RAID and non-RAID hard disks (NVMe SSD), it displays the RAID conguration option. However, the non-RAID disks
are not displayed on RAID conguration page.
• When you update the rmware on a Broadcom NetXtreme and QLogic BCM57xx and BCM57xxx (previously known as Broadcom
NetXtreme ||) adapters, the following issue occurs: After installing the QLogic-specic rmware update package on the BCM57xx or
BCM57xxx adapter family, the rollback version is not available if the previously installed rmware was provided by a legacy shared
rmware update package. However, if the legacy shared rmware version is available as a rollback version for the Broadcom NetXtreme
adapter, then the same version will be available for the QLogic BCM57xx and BCM57xxx adapters.
The issue occurs because separate rmware update packages are provided for the Broadcom NetXtreme adapters and QLogic
BCM57xx and BCM57xxx adapters due to the acquisition of the Broadcom NetXtreme || cards by QLogic. Prior to the acquisition, a
common shared rmware update package was provided.
• The following Intel cards do not support rmware rollback and may not display all the ports on the Comparison page while updating the
rmware:
– Intel Ethernet Converged Network Adapter X710 - Quad Port
– Intel Ethernet Converged Network Adapter X710 - Dual Port
– Intel Ethernet Converged Network Adapter XL710
– Intel Ethernet 10G 4P X710/1350 rNDC
– Intel Ethernet 10G 4P X710 SFP + rNDC
– Intel Ethernet 10G 4P X710-k bNDC
– Intel Ethernet 10G 2P X710-k bNDC
– Intel Ethernet 40G 2P XL710 QSFP + rNDC
– Intel Gigabit I350-t LOM
– Intel(R) Ethernet 10G X520 LOM
– Intel(R) Ethernet 10G 2P X550-t Adapter
• While installing the operating system on 12th generation PowerEdge servers by using LC UI, ensure that the virtual media is attached on
the server before BIOS boot.
• On NANO operating system, you cannot install a rmware or driver DUP if it is in .exe format.
• During the RAID Conguration, on the Step 3 of 5: Select Physical Disk page, the scroll bar of Select Physical Pool table is not
displayed. To view the scroll bar:
– Hover your mouse over the right edge of the table.
14
Limitations