1 The drivers exposed by LC are present in a read-only drive labeled OEMDRV and the drive is active for 18 hours. During this period:
You cannot install any DUPs.
LC cannot invoke CSIOR.
However, if an AC power cycle (cold boot) is performed, the OEMDRV drive is automatically deleted.
2 CPLD rmware update has no impact on Trusted Platform Module enablement.
3 Depending on the virtual storage device attached through iDRAC, that is, USB drive or CD/DVD .ISO le, LC displays Virtual Floppy
or Virtual CD respectively.
4 If Test Network Connection fails for a valid address, try conguring the network settings again. If the issue persists, restart the system
and retry the operation.
5 When you reset or update the iDRAC, you must reboot LC if it is launched already. If you fail to reboot, LC may behave unexpectedly.
6 On PowerEdge FC630, PowerEdge FC830, and PowerEdge FC430 systems, part replacement is not supported if a single PERC
(FS332) is replaced with a dual PERC (FD332) or vice-versa.
7 After performing a rmware update or rollback operations from LC, the host is rebooted by default. Reboot the host server again to
display the updated rmware versions in the View Current Versions wizard.
8 To record updates in the Lifecycle Log, ensure that the Lifecycle Controller and iDRAC are from the same release.
9 If Lifecycle Controller and iDRAC are not from the same release, the Lifecycle Log displays either blank messages or messages with a
~ character.
10 When you update a 12
th
generation PowerEdge server backplane-expander rmware for PowerEdge R920 rmware to version 0.33 or
2.03, the comparison page displays only one expander entry. However, rmware for both the expanders is updated.
11 Fibre channel NIC cards with two or four ports are displayed as a single port card in Lifecycle Controller. However, all ports are
updated when a rmware update is performed.
12 The option to enable or disable the disk cache policy for SWRAID controllers is supported only on SWRAID controller driver version
4.1.0-0025 or later.
13 ResetKeys under Action in the SecureBoot resource is available only on systems with supported BIOS.
14 The SecureBoot navigation link is available under Computer System only if the SecureBoot feature is supported by the BIOS installed
on the system.
15 Rollback is not supported for CPLD.
16 If SMBv2 share fails in Lifecycle GUI, ensure that:
the Digitally sign communications option is disabled
permissions to access the folder/le are granted
folder/le name does not have a space
share contains fewer les and folders