Reference Guide
Version 7.5.1.0 Introduced on the C-Series.
pre-Version
6.1.1.0
Introduced on the E-Series.
Usage
Information
You can change the order of the month and day parameters to enter the time and date as time
day month year.
In the switch, the hardware clock is separate from the software and is called the calendar.
This hardware clock runs continuously. After the hardware clock (the calendar) is set, the
FTOS automatically updates the software clock after system bootup. You cannot delete the
hardware clock (calendar).
To manually update the software with the hardware clock, use the clock read-
calendar command.
Example
FTOS#calendar set 08:55:00 june 18 2006
FTOS#
Related
Commands
clock read-calendar — sets the software clock based on the hardware clock.
clock set — sets the software clock.
clock update-calendar — sets the hardware clock based on the software clock.
show clock — displays the clock settings.
clock read-calendar
Set the software clock on the switch from the information set in hardware clock (calendar).
Z-Series
Syntax
clock read-calendar
Defaults Not configured.
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
1386