Reference Guide
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series, S55.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Usage
Information
To block a type of message parameter, set the logging trap level to a lower number. For
example, to block severity messages at level 6, set the level to 5.
Related
Commands
logging — enables the logging to another device.
logging on — enables logging.
show logging
Display the logging settings and system messages logged to the internal buffer of the switch.
Z-Series
Syntax
show logging [number | history [reverse][number] | reverse
[number] | summary]
Parameters
number
(OPTIONAL) Enter the number of messages displayed in the output.
The range is from 1 to 65535.
history (OPTIONAL) Enter the keyword history to view only information in
the Syslog history table.
reverse (OPTIONAL) Enter the keyword reverse to view the Syslog
messages in FIFO (first in, first out) order.
summary (OPTIONAL) Enter the keyword summary to view a table showing
the number of messages per type and per slot. Slots *7* and *8*
represent RPMs.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
1340