Reference Guide

Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.2.1.0 Introduced on S-Series Stacking.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.7.1.0 Introduced on the S-Series.
Version 7.6.1.0 Introduced on the C-Series.
Version 6.2.1.1 Introduced on the E-Series.
Usage
Information
This command changes the sampling rate for an interface. By default, the sampling rate of an
interface is set to the same value as the current global default sampling rate. If the value
entered is not a correct power of 2, the command generates an error message with the
previous and next power-of-2 value. Select one of these two number and re-enter the
command.
Related
Commands
sflow sample-rate (Global) — changes the sampling rate globally.
show sflow
Display the current sFlow configuration.
Z9000
Syntax
show sflow [interface]
Parameters
interface
(OPTIONAL) Enter the following keywords and slot/port or number
information:
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a Port-Channel Ethernet interface, enter the keyword
port-channel then the slot/port information. The range is
from 1 to 128.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
1303