Owner's Manual

Dell 8/4Gbps FC SAN Module Administrator’s Guide 53
53-1001345-01
portCfgShow
B
LM The link is up to 25 km.
L1 The link is up to 50 km.
L2 The link is up to 100 km.
LD The distance is determined dynamically.
LS The distance is determined statically by user input.
This value is set by the portCfgLongDistance command.
VC Link Init Displays (..) or OFF when the long distance link initialization option is turned
off. Displays ON when it is turned on for long distance mode. This value is set
by the portCfgLongDistance command.
Locked L_Port Displays ON when the port is locked to L_Port only. Displays (..) or OFF when
L_Port lock mode is disabled and the port behaves as a U_Port). This value is
set by the portCfgLport command.
Locked G_Port Displays ON when the port is locked to G_Port only. Displays (..) or OFF when
G_Port lock mode is disabled and the port behaves as a U_Port. This value is
set by the portCfgGport command.
Disabled E_Port Displays ON when the port is not allowed to be an E_Port. Displays (..) or OFF
when the port is allowed to function as an E_Port. This value is set by the
portCfgEport command.
ISL R_RDY Mode Displays ON when ISL R_RDY mode is enabled on the port. Displays (..) or OFF
when ISL R_RDY mode is disabled. This value is set by the portCfgISLMode
command.
RSCN Suppressed
Displays ON when RSCN suppression is enabled on the port. Displays (..) or
OFF when RSCN suppression is disabled. This value is set by the portCfg
rscnsupr command.
Persistent Disable Displays ON when the port is persistently disabled; otherwise displays (..) or
OFF. This value is set by the portCfgPersistentDisable command.
NPIV capability Displays ON when N_Port ID Virtualization (NPIV) is enabled on the port
(default). Displays (..) or OFF when NPIV capability is disabled. This value is
set by the portCfgNPIVPort command.
QOS E_Port Displays ON when Quality of Service (QoS) is enabled on the E_Port (or
EX_Port) when QoS is enabled in an FCR deployment scenario. Displays (..) or
OFF when QoS is disabled. By default, QoS is enabled if sufficient buffers are
available. Displays AE when QOS is configured as Auto Enabled. In the AE
state, QoS is enabled based on the availability of buffers. Use islShow to
determine the current status of QoS (on or off) in the AE state. This value is
set by the portCfgQos command.
EX_port. Displays ON when the port is configured as an EX_Port. Otherwise displays (..)
or OFF. This value is set by the portCfgExPort command.
Mirror Port Displays ON when Mirror Port is enabled on the port. Displays (..) or OFF when
Mirror Port is disabled. This value is set by the portCfg mirrorport command.