Table 2-3: Minimum Network Configuration Component Descriptions
Callout Description
1 Switch stack (used for both client and internal connections)
2, 3 FS7500 Controllers
EqualLogic FS7500 Controller Hardware Maintenance Installing System Components
2–10
Figure 2-7: EqualLogic FS7500 Network Configuration – Minimum
Connecting SAN and Internal Network Cables
For the recommended configuration, see Figure 2-6. For each controller, use nine network cables
to make the following controller connections to the two switch stacks:
All the ports on the two top network interface cards.
Single port in the lower-left corner of the controller.
Note: Be sure to distribute the internal network and SAN connections across the two switches
for high availability.
For the minimum configuration, see Figure 2-7. For each controller, use four network cables to
make the following controller connections to the same switch stack:
First and third port in the top-left network interface card.
First port in the top-right network interface card.
Single port in the lower-left corner of the controller.