Install Guide

FS7500 Controller Technical Specifications
Table 2: FS7500 Controller Technical Specifications
Attribute Value
Weight of controller 39 pounds or 17.69 kilograms
Operating temperature 50 to 95 degrees F (10 to 35 degrees C)
Storage temperature -40 to 149 degrees F (-40 to 65 degrees C)
Operating altitude -50 to 10,000 feet (-16 to 3048 meters)
Operational relative humidity 20 to 80 percent non-condensing
Thermal output (fully-loaded controller)
2446.5 BTU/hr maximum (High Output)
1712.9 BTU/hr maximum (Energy Smart)
Operational shock
Half sine shock in all operational orientations of 31G plus or
minus 5% with a pulse duration of 2.6 ms plus or minus 10%
Operational vibration
0.26 Gms from 5-350 Hz for 5 minutes in operational
orientations
Input voltage 90 to 264 VAC (auto-sensing)
Input frequency 47 - 63 Hz
System input power 90-264 VAC, autoranging, 47-63 Hz
Each power supply
502 W
Input current: up to 55 A per power supply for 10 ms or less
Dimensions
1.68 in. height x 18.99 in. width x 30.39 in. depth
(4.26 cm height x 48.24 cm width x 77.2 cm depth)
FS7500 Backup Power Supply Technical Specifications
Table 3: FS7500 Backup Power Supply Technical Specifications
Attribute Value
Weight of fully-loaded BPS 66.1 pounds (30 kilograms)
Operating temperature 32 to 104 degrees F (0 to 40 degrees C)
Storage temperature 5 to 113 degrees F (-15 to 45 degrees C)
Operating altitude 10,000 feet (3048 meters)
Operational relative humidity 0 to 95 percent non-condensing
Input voltage
120 V models: 90-140 V, auto-sensing
230 V models: 180-264 V, auto-sensing
Input frequency 50 - 60 Hz (auto-sensing), +/- 3 Hz
Power levels 500 W DC output
Dimensions 17.1 in. x 1.6 in. x 28.5 in. (434 cm x 42 cm x 723 cm)
6
EqualLogic FS7500 Installation and Setup
1 Before You Begin