User Guidelines
This command is available from the Unit prompt on a member unit serial
port. The user need not be currently connected over the serial port to connect
to another unit.
The stack member being connected to must be up and running and
connected as part of the stack. This command connects the the serial console
from the target stack member to the local unit. There is only one console
session allowed per stack. The remote console session is not restarted and the
privilege level is not changed as a result of being connected to the local unit.
All security mechanisms applicable to the serial port remain in place.
Example
Example 1:
To connect to a remote stack member from master.
Stack-Master#connect 2
Remote session started. Type "exit" to exit the session.
(Unit 2 - CLI unavailable - please connect to master on Unit 1)>
Example 2:
To connect to the stack master (unit 1, below) over a stack member serial
port.
(Unit 2 - CLI unavailable - please connect to master on Unit 1)>connect 1
Stack-Master#
disconnect
Use the disconnect command to detach a UI session.
Syntax
disconnect { session-id | all }
Default Configuration
This command has no default configuration.