Users Guide

Table Of Contents
Connectivity Fault Management 1041
2
Configure port 1/0/5 as an MEP for service VLAN 200 so that the port can
exchange CFM PDUs with its counterpart MEPs on the customer
network. The port is first configured as a MEP with MEP ID 20 on domain
level 6 for VLAN 200. Then the port is enabled and activated as a MEP.
console(config)#interface gigabitethernet 1/0/5
console(config-if-Gi1/0/5)#ethernet cfm mep level 6
direction
down mpid 20 vlan 200
console(config-if-Gi1/0/5)#ethernet cfm mep enabled level 6
vlan 200 mpid 20
console(config-if-Gi1/0/5)#ethernet cfm mep active level 6
vlan 200 mpid 20
console(config-if-Gi1/0/5)#exit
3
On an intermediate switch, configure the MIP for the customer domain
and enable CFM services on the CustDom domain to include local