Command Line Interface Guide

Table 24. Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=<
index
> NA Specifies the LCD line number.
config=none | default |
custom
NA
none: Sets the LCD text to none.
default: Sets the LCD text to default.
custom: Sets the LCD text to custom.
text=<
custom text
> NA Sets the custom text for LCD when config=custom.
nmibutton=enable | disable NA
enable: Enables the NMI button on the system.
disable: Disables the NMI button on the system.
powerbutton=enable |
disable
NA
true: Enables the Power button on the system.
false: Disables the Power button on the system.
config=sysname NA Sets the name of the system.
config=syspower NA Sets the system power information.
config=servicetag NA Sets the system service tag information.
config=remoteaccessipv4 NA Sets the remote access IPv4 information.
config=remoteaccessipv6 NA Sets the remote access IPv6 information.
config=remoteaccessmac NA Sets the remote access MAC address.
config=ipv4idrac Sets IPv4 DRAC information.
config=ipv6idrac Sets IPv6 DRAC information.
config=macidrac NA Sets the DRAC’s MAC address.
config=ambienttemp NA Sets the system temperature in centigrade.
security=modify NA Allows you to modify the LCD text.
security=view NA Provides read-only access to the LCD text.
security=disabled NA Provides limited access to the LCD text.
remoteindication=true NA LCD flashes when the system detects an active remote session.
NOTE: The options ipv4idrac, ipv6idrac, and macidrac are deprecated.
Omconfig Chassis Info Or Omconfig Mainsystem Info
Use the omconfig chassis info or omconfig mainsystem info command to enter an asset tag name and a chassis name
for the system. For a blade systems, enter asset tag names for modular components as well. The following table displays
the valid parameters for the command: