SNMP Reference Guide
724 Traps
Voltage Probe Failure
1154 Voltage sensor detected a
failure value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Error A voltage sensor in the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous state,
and voltage sensor value
are provided.
Voltage Probe Nonrecoverable
1155 Voltage sensor detected a
non-recoverable value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Error A voltage sensor in the
specified system
detected an error from
which it cannot recover.
The sensor location,
chassis location,
previous state, and
voltage sensor value are
provided.
Table 27-5. Voltage Probe Traps
(continued)
Trap ID Description Severity Cause
book.book Page 724 Monday, March 14, 2011 3:01 PM