Messages Reference Guide
Storage Management Message Reference
197
2347 The rebuild
failed due to
errors on the
source physical
disk.
Critical /
Failure / Error
Hardware RAID:
Cause:
Yo u a r e
attempting to rebuild
data that resides on a
defective disk.
Action:
Replace the
source disk and restore
from backup.
Software RAID:
•Perform a backup
with the Verify
option.
• If the file backup
fails, try to restore the
failed file from a
previous backup.
• When the backup
with the Verify option
is complete without
any errors, delete the
Virtual Disk.
• Recreate a new
Virtual Disk with new
drives.
• Restore the data from
backup.
Clear Alert:
None
Related Alert
Number:
2195, 2346
LRA Number:
2071
904
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers