Command Line Reference Guide

cfgTrapsAlertDestIpAddr=
cfgTrapsCommunityName=public
cfgRacTuning
This group is used to configure various iDRAC or CMC configuration properties, such as valid ports and security port
restrictions.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE: For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the
-o option.
Use the -m option to apply this setting to iDRAC.
The following sections provide information about the objects in the cfgRacTuning group.
cfgRacTuneConRedirPort (Read/Write)
Description Specifies the port to be used for keyboard, mouse, video,
and Virtual Media traffic to iDRAC.
This object is applicable only to iDRAC.
Legal Values 1024 – 65535
Default 5900
cfgRacTuneRemoteRacadmEnable (Read/Write)
Description Enables or disables the Remote RACADM interface in
iDRAC or CMC.
Legal Values
1 (TRUE)
0 (FALSE)
Default 1
cfgRacTuneCtrlEConfigDisable
Description Enables or disables the ability of the local user to
configure iDRAC from the BIOS POST option-ROM.
This object is applicable only for iDRAC on Rack and
Tower Servers and not for iDRAC Enterprise on Blade
Servers or CMC.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
171