Users Guide
Table Of Contents
- Dell Command | Monitor Version 10.3 User's Guide
- Introduction to Dell Command | Monitor 10.3
- Windows SMM Security Mitigations Table (WSMT) Compliance
- Standards and protocols for Dell Command | Monitor 10.3
- Use case scenarios using Dell Command | Monitor 10.3
- Using Dell Command | Monitor 10.3
- Polling interval setting
- RAID status reporting
- Monitoring the Dell client systems
- Application log for Dell Command | Monitor for Linux
- Detecting advance format drives
- Boot configurations
- Changing the system settings
- Managing Dell client systems locally using Dell Command | Monitor 10.3
- Managing Dell client systems remotely using Dell Command | Monitor 10.3
- Frequently asked questions for Dell Command | Monitor 10.3
- Troubleshooting steps using Dell Command | Monitor 10.3
- Unable to remotely connect to Windows Management Instrumentation
- Installation failure on systems running Windows
- BIOS setting enumeration value appears as 1
- Hapi installation fails due to the dependency of libsmbios
- CIM resources not available
- Unable to execute the commands using DCM on the systems running Ubuntu Core 16
- Third-party licenses
- Other documents you may need
- Contacting Dell
NOTE: Monitoring of Intel-integrated controller is not supported for the systems running Linux operating system.
In sensor monitoring, Dell Command | Monitor supports monitoring and alerting of voltage, temperature, amperage, cooling
devices (fan) and chassis sensors.
For more information about class and alerting, see Dell Command | Monitor Reference guide at dell.com/
dellclientcommandsuitemanuals.
Can Dell Command | Monitor be integrated with other applications/consoles?
Yes, Dell Command | Monitor interfaces with leading enterprise management console that support industry standards. It can be
integrated with the following existing enterprise management tools:
● Dell Client Integration Suite for System Center 2012
● Dell OpenManage Essentials
● Dell Client Management Pack for System Center Operation Manager
Can I import classes into SCCM for inventory?
Yes, individual MOFs or OMCI_SMS_DEF.mof files can be imported in SCCM console for inventory.
Where is the SCCM OMCI_SMS_DEF.mof file located?
The OMCI_SMS_DEF.mof file is at C:\Program Files\Dell\Command_Monitor\ssa\omacim\OMCI_SMS_DEF.mof.
How to configure proxy for DCM 10.2.1?
DCM 10.2.1 is unable to fetch warranty information.
Check if the Application proxy settings are correctly configured using DCIM_ApplicationProxySetting Class.
How can I configure a Proxy credential for Dell Command | Monitor.
If you have logged in through Dell Command | Monitor, you can use the same credentials for proxy authentication.
26