User's Manual

366 I/O Fabric Management
4
Click the
Status
subtab. The
I/O Modules Status
page displays.
Table 11-1. I/O Modules Status Information
Item Description
Slot Displays the location of the I/O module in the chassis by group
number (A, B, or C) and Bank (1 or 2). IOM Enumeration: A1, A2,
B1, B2, C1, or C2.
Present Displays whether the IOM is present (Yes or No).
Health OK Indicates that the IOM is present and
communicating with CMC. In the event of a
communication failure between CMC and the
server, CMC cannot obtain or display health
status for the IOM.
Informational Displays information about the IOM when no
change in health status (OK, Warning, Severe)
has occurred.
Warning Indicates that warning alerts have been issued,
and corrective action must be taken. If
corrective actions are not taken, it could lead to
critical or severe failures that can affect the
integrity of the IOM.
Examples of conditions causing Warnings: IOM
fabric mismatch with the server's mezzanine
card fabric; invalid IOM configuration, where
the newly installed IOM does not match the
existing IOM on the same group.
Severe Indicates that at least one Failure alert has been
issued. Severe status represents a system failure
on the IOM, and corrective action must be
taken immediately.
Examples of conditions causing Severe status:
Failure in IOM detected; IOM was removed.
NOTE: Any change in health is logged to both the hardware and CMC
log. For more information, see "Viewing the Event Logs" on page 398.