CLI Guide

Table 73. Details of getsysinfo (continued)
NOTE: In the Chassis Information output, the PCIe Switch Board Type information
is displayed only for PowerEdge FX2s chassis model.
Examples
racadm getsysinfo -d
racadm getsysinfo -c
racadm getsysinfo -A
racadm getsysinfo -4
racadm getsysinfo -6
gettracelog
Table 74. Details of gettracelog
Description Lists all the trace log entries in CMC.
Synopsis racadm gettracelog -i [-A]
racadm gettracelog [-s <start>] [-c <count>] [--more] [-A] [-o]
Input -i—Displays the number of entries in CMC trace log.
- -more—Displays one screen at a time and prompts the user to continue (similar to the UNIX more
command).
-o—Displays each entry in a single line.
-c—Specifies the number of records to display.
-s—Specifies the starting record to display.
-A—Does not display headers or labels.
NOTE: The -A and -o options are deprecated.
Output The default output display shows the record number, timestamp, source, and description. The
timestamp begins at midnight, January 1 and increases until the system boots. After the system boots,
the timestamp of the system timestamp is used.
Example Display entire log
racadm gettracelog
Display number of records in log
racadm gettracelog -i
getversion
Table 75. Details of getversion
Description
Displays the current software version, model and generation information, and whether the target
device can be updated.
RACADM Subcommand Details 65