Defect ID: DEFECT000588840
Technical Severity: Medium
Probability: High
Product: Brocade Fabric OS
Technology: Monitoring
Reported In Release: FOS8.0.1
Technology Area: D_Port -
Diagnostic Port
Symptom: D_Port fails when DWDM is applied to it
Condition: When DWDM is enabled on a port configured as D_Port.
Workaround: Disable the D_Port configuration using "portcfgdport --
disable <port #>" and then execute the command "portcfgdport --enable
-dwdm <port #>"
Defect ID: DEFECT000589666
Technical Severity: High
Probability: High
Product: Brocade Fabric OS
Technology: Extension
Reported In Release: FOS8.0.1
Technology Area: FCIP -
Fibre Channel over IP
Symptom: Loss of device connectivity during non-disruptive firmware
migration on Brocade 7840
Condition: Occasional during a non-disruptive firmware migration on an
extension platform, when DP upgrade is happening, frames are dropped
when the routes change to support DP fail over and DP fallback process
Defect ID: DEFECT000590383
Technical Severity: Medium
Probability: Low
Product: Brocade Fabric OS
Technology: Security
Reported In Release: FOS7.3.1
Technology Area: Fabric
Authentication
Symptom: Certain devices are denied access to login to the switch when
they have a DCC policy configured with proper WWNs.
Condition: This may occur when either of the WWN words have the most
significant bit set. For example WWNs like c0:xx:xx:xx:xx:xx:xx:xx or
xx:xx:xx:xx:c0:xx:xx:xx might see this problem when DCC is configured.
Defect ID: DEFECT000590472
Technical Severity: Medium
Probability: Medium
Product: Brocade Fabric OS
Technology: Monitoring
Reported In Release: FOS8.0.1
Technology Area: Flow
Vision
Symptom: Sort by option for flow --show in sys_mon_all_F_Ports does
not take the sid column into consideration.
Condition: When flow --show sys_mon_all_F_Ports -sortby column2
CLI is executed, it takes the DID column to sort the output instead of the
SID column.