Setup Guide

Fabric OS 8.0.1 Release Notes v1.0 Limitations and Restrictions: Defects
Page 94 of 107
Symptom: The GE ports of the SX6 extension blade displays the port state
as "No_Light" rather than "Mod_Inv" when a 32G SFP+ is inserted
Condition: When a 32G SFP+ is inserted into the GE port of a SX6
extension blade.
Defect ID: DEFECT000583693
Technical Severity: High
Probability: Medium
Product: Brocade Fabric OS
Technology: Extension
Reported In Release: FOS8.0.1
Technology Area: FCIP -
Fibre Channel over IP
Symptom: FCIP circuit spillover feature may not meet expectations
Condition: When the tunnel's bandwidth is not fully saturated or utilized.
As in the case a tunnel's throughput is below the configured bandwidth
and the bandwidth is modified, the actual throughput may move in the
opposite direction from the bandwidth value modified. The bandwidth of
a tunnel can change based on the circuit's bandwidth changing, tunnel's
load-level algorithm changing, and/or the metric of a circuit changing.
Workaround: There is no predictable configuration since the host
application's configured block sizes and outstanding I/Os can vary.
Defect ID: DEFECT000585585
Technical Severity: High
Probability: High
Product: Brocade Fabric OS
Technology: Monitoring
Reported In Release: FOS8.0.1
Technology Area: D_Port -
Diagnostic Port
Symptom: Spinfab test may fail to run successfully on ports configured as
D_Ports when attached to a Qlogic HBA. Functionality of the switch is not
affected.
Condition: Spinfab failure maybe observed when running on a port
configured as D_Port attached to a Qlogic HBA with "-F_Ports 1" option
Defect ID: DEFECT000585875
Technical Severity: Medium
Probability: Medium
Product: Brocade Fabric OS
Technology: Monitoring
Reported In Release: FOS8.0.1
Technology Area: Flow
Vision
Symptom: System-defined flow does not collect flow monitor stats for
F_Port trunks.
Condition: When a system defined flow "sys_mon_all_F_Port" is activated
on a switch which has F_Port trunk. After a few portdisable/portenables
of the slave ports, it has been observed that stats are not displayed for
master F_Port.