Defect ID: DEFECT000567870
Technical Severity: High
Probability: High
Product: Brocade Fabric OS
Technology: Management
Reported In Release: FOS8.0.0
Technology Area:
Management GUI
Symptom: "IP filter operation is not allowed in this switch instance" error
message when configuring an IP filter
Condition: When an IP Filter configuration is performed on logical switch
context
Defect ID: DEFECT000569827
Technical Severity: Low
Probability: Low
Product: Brocade Fabric OS
Technology: Management
Reported In Release: FOS8.0.0
Technology Area: Fibre
Channel Services
Symptom: Port beaconing stops after spinfab is ran.
Condition: When port beaconing is enabled on a port, LED blink pattern
stops after spinfab is ran.
Recovery: Disable and then re-enable port beaconing on the port.
Defect ID: DEFECT000569927
Technical Severity: Low
Probability: Low
Product: Brocade Fabric OS
Technology: Management
Reported In Release: FOS8.0.0
Technology Area:
Management GUI
Symptom: The speed display in the WebTools Switch Throughput Graph is
not display the X-axis correctly for the G620 switch.
Condition: The X-axis display problem occurs for all GEN6 platforms
Workaround: Maximize the Web Tools Switch Throughput Graph for
proper display
Defect ID: DEFECT000570383
Technical Severity: Medium
Probability: Low
Product: Brocade Fabric OS
Technology: Traffic
Management
Reported In Release: FOS7.3.1
Technology Area: FICON
Symptom: Soon after a CFG-POR (mainframe reboot) operation, channels
in a Logical Switch lost connectivity with Control Units in its neighbor
Logical Switch. At the point of lost connectivity, all Logical Fabrics lost
connectivity through the Base Fabric to their common-zoned targets in the
remote Logical Fabric.