Users Guide

Recover or rebuild a degraded virtual drive
You can manually rebuild a degraded virtual disk. RAID rebuild is available only when a degraded RAID volume is present and
there is an available target device. If a foreign virtual disk is in rebuild state, rebuild starts automatically after you import the
virtual disk and reboot the server. Clear configuration operation does not affect any background activity, like rebuild.
Erase physical disk data
About this task
NOTE: Erase physical disk is not supported when the physical disk is a part of virtual disk.
Steps
1. Enter the BOSS-S2 Configuration Utility. See Enter the BOSS-S2 Configuration Utility.
2. Click Erase Physical Disk.
3. Select the devices by selecting the check box next to the available physical disk configuration.
4. Select Yes for the option Would you like to erase this Physical Disk?.
5. Click Next.
After the physical disk is successfully erased, the Physical Disk information tab shows the physical disk status as
unconfigured.
View RAID controller information
About this task
The Controller information menu allows you to view the properties of the RAID Controller.
Steps
1. Enter the BOSS-S2 configuration utility. See Enter the BOSS-S2 Configuration Utility.
2. Click Controller information.
The RAID adapter information is displayed.
Clear RAID controller configuration data
About this task
The clear configuration operation is used to clear RAID metadata from the adapter.
NOTE: The clear configuration operation does not delete any data on the virtual disk.
Steps
1. Click Controller information.
2. Select Clear Config.
3. Click OK.
32
BOSS-S2 UEFI configuration utility