Instruction manual

25-PIN CABLE ELECTRICAL CONNECTIONS
73
5
5.8 INPUTS
There are two optocoupled polarity insensitive inputs available on the 25-pin connector of the
reader: Input 1 (External Trigger) and Input 2, a generic input:
The External Trigger can be used in One Shot Mode or in Phase Mode. Its main functions
are:
acquisition trigger in One Shot Mode
reading phase-ON/reading phase-OFF command in Phase Mode
The main functions of the general purpose Input 2 are:
second external trigger in Phase Mode
match code storage command when the Match Code option is enabled
The electrical features of both inputs are:
Maximum voltage: 30 Vdc
Maximum current: 12 mA
The active state of these inputs are selected in software. Refer to the VisiSetâ„¢ Help On
Line.
An anti-disturbance filter is implemented in software on both inputs so that the minimum
pulse duration is 0.5 milliseconds. This value can be increased through the software
parameter Debounce Filter, see the Digital I/O folder in the VisiSetâ„¢ Help On Line for further
details.
These inputs are optocoupled and can be driven by both NPN and PNP type commands.
NOTE
Polarity insensitive inputs assure full functionality even if pins A and B are
exchanged.
The connections are indicated in the following diagrams:
Pin
Name
Function
9
Vdc
Power Supply input voltage +
18
I1A
External Trigger A (polarity insensitive)
19
I1B
External Trigger B (polarity insensitive)
7
GND
Power Supply input voltage -
The yellow Trigger LED (Figure 15, 5) is on when the active state of the External Trigger
corresponds to ON.