113
MULTIPLE LABEL READING
In standard (default) mode, when the readers aiming system is activated (by
a trigger pull, motion or other method depending on the mode), it then
acquires and processes each image in the area in front of it (the Volume). In
this case, the scanner stops processing the image once it decodes a label. If
several labels are present in the volume, only the first label encountered is
decoded and sent.
When Multiple Reading Mode is enabled, the scanner keeps on processing
the
image until all the labels present are decoded. The reader then sorts the
data from all the bar codes (if configured to do so) before transmitting it.
Multiple Labels per Frame
Specifies the ability of the reader to decode and transmit a set of code labels
in a specific volume and in a single frame of time. When in Multiple Labels
per Frame the reader beeps and turns on the good read LED indication for
each code read in a frame.
When Multiple Labels Mode is enabled, ISB
T pairing, ABC Codabar pairing,
and composites are not allowed.
Multiple Labels per Frame = Disable
Multiple Labels per Frame = Enable
DEFAULT
$CSNML00(CR)
$CSNML01(CR)