Datasheet

www.datalogic.com
The model is equipped with a polarization filter to avoid false
switching due to reflective objects. The absence of the trimmer is
compensated by the availability of two different models:
-a short range model, suggested for the conveyor belts and
applications with small detection area, especially in the detection
of critical materials (shiny packages, reflective surfaces, metallic
parts, glossy plastic objects, ceramic tiles)
-a long range model, usable in generic applications and for long
distance object detections
The SLIT accessory is available with three different aperture
dimensions to further reduce the emission power and to narrow
the light beam.
The reflector is not included with the product.
POLARIZED RETROREFLECTIVE
SLIT EFFICIENCY
The use of the rectangular SLIT (0,5/1/2 mm x
19 mm), available as accessory, allows to reduce
the power and the openess of the light beam,
in order to avoid optical interference between
adjacent sensors and to narrow the light beam
facilitating the detection of smaller objects.
REFLECTOR TYPE
SHORT RANGE
(S100-…-B0)
LONG RANGE
(S100-…-B1)
R1 circular (Ф 23 mm) 0,1..0,8 m 0,02..2 m
R2 circular (Ф 48 mm) 0,03..2 m 0,01..4,5 m
R3 rectangular(18x54 mm) 0,03..1,5 m 0,01..3 m
R4 rectangular(47x47 mm) 0,03..2,5 m 0,01..4,5 m
R5 circular (Ф 75 mm) 0,01..3 m 0,01..5,5 m
R6 rectangular(36x55 mm) 0,03..1,8 m 0,01..4 m
RT3970
self-adhesive tape (60x40 mm)
0,1..0,8 m 0,05..1,8 m
max. operating distance
SHORT RANGE (S100-…-B0) LONG RANGE (S100-…-B1)
with R5 reflector with R2 reflector with R5 reflector with R2 reflector
NO SLIT
0,02 … 3,5 m 0,02 … 2,3 m 0,1...6,15 m 0,01...5,15 m
2 mm SLIT
0,05 … 1,7 m 0,05 … 1 m 0,2...4,4 m 0,03...3,5 m
1 mm SLIT
0,1 … 0,55 m 0,1 … 0,3 m 0,3...3 m 0,05...2,1 m
0,5 mm SLIT
not usable not usable 0,5...1,5 m 0,07...1 m
POLARIZED RETROREFLECTIVE (SHORT RANGE: S100-B00)
POLARIZED RETROREFLECTIVE (LONG RANGE: S100-B10)
Miniature Sensors - S100
-100
-80
-60
-40
-20
0
20
40
60
80
100
0 1000 2000 3000 4000 5000 6000
Detection Area [mm]
Distance [mm]
Detection Area
Polarized retroreflective (long range)
(S100-B10) on R2 reflector
NO SLIT
SLIT 2 mm
SLIT 1 mm
SLIT 0.5 mm
-120
-100
-80
-60
-40
-20
0
20
40
60
80
100
120
0 1000 2000 3000 4000 5000 6000 7000
Detection Area [mm]
Distance [mm]
Detection Area
Polarized retroreflective (long range)
(S100-B10) on R5 reflector
NO SLIT
SLIT 2 mm
SLIT 1 mm
SLIT 0.5 mm
-40
-20
0
20
40
0 500 1000 1500 2000 2500
Detection area [mm]
Distance [mm]
Detection Area:
Polarized Retroreflective (short range)
(S100-B01) on R2 reflector
NO SLIT
SLIT 2 mm
SLIT 1 mm
SLIT 0.5 mm
-80
-60
-40
-20
0
20
40
60
80
0 500 1000 1500 2000 2500 3000 3500 4000
Detection area [mm]
Distance [mm]
Detection Area:
Polarized Retroreflective (short range)
(S100-B01) on R5 reflector
NO SLIT
SLIT 2 mm
SLIT 1 mm
SLIT 0.5 mm