User Manual

AlarmView™ System Administrator’s Manual
Part #880-0326-01 REV. 10/4/2000 Appendix B-5
4. Enter the cap codes of all the pagers to be installed in the care
unit, up to 12 pagers, into the AlarmView programmer. (See
Section 4: Programming.)
Transmitter Setup
The purpose of this activity is to set up each transmitter in the system.
For each transmitter in the system, perform the following steps:
1. Turn on the transmitter.
2. With the programmer, use the AlarmView Install program. Begin
by pressing CHECK.
3. Program the appropriate frequency, baud rate, and common cap
code into the transmitter. Press the SEND button.
4. Set the Reminder Time Interval according to the care unit’s
policy. If no policy is established, suggest to the nurse manager
that it be set to 2 minutes. Press the SEND button.
5. Set the Range Test (Survey Page) to transmit at 15-seconds
intervals for 100 pages. Press the SEND button.
6. Use the CHECK button to verify that all the above values were
properly received by the transmitter.
Setup Verification
The purpose of this activity is to ensure that all transmitters are correctly
transmitting to all the pagers and the programmer is properly setup.
The following steps verify that the Programmer and Pagers have the
correct Common Cap Code.
1. Turn on one transmitter and all the pagers.