Daikin EHK Installation Manual

WARNING
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING
THIS UNIT.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE
TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
CAUTION
TO AVOID POSSIBLE PERSONAL INJURY, USE EXTREME CAUTION IF USING
POWER TOOLS TO REMOVE THE SMALL BREAKER MOUNTING BRACKETS.
T
HE
BRACKETS MAY QUICKLY ROTATE AND CAUSE INJURY.
INSTRUCTIONS
1. Disconnect all power to the unit, both indoor and outdoor.
2. Remove control box door.
3. Remove blower door.
4. Remove heat access door.
5. Locate heater box. Remove screws holding the heater box
cover in place (Figure 1).
CONTROL BOX
DOOR
HEAT
ACCESS
DOOR
HEAT BOX
COVER
BLOWER
DOOR
Figure 1
Attention Installing Personnel
As a professional installer, you have an obligation to know the
product better than the customer. This includes all safety precau-
tions and related items.
Prior to actual installation, thoroughly familiarize yourself with this
Instruction Manual. Pay special attention to all safety warnings.
Often during installation or repair, it is possible to place yourself in
a position which is more hazardous than when the unit is in op-
eration.
Remember, it is your responsibility to install the product safely
and to know it well enough to be able to instruct a customer in its
safe use.
Safety is a matter of common sense...a matter of thinking before
acting. Most dealers have a list of specific good safety
practices...follow them.
The precautions listed in this Installation Manual are intended as
supplemental to existing practices. However, if there is a direct
conflict between existing practices and the content of this manual,
the precautions listed here take precedence.
Description
The following installation instructions supplement is for the EHK
heater kits for installation in the following models:
**C036, **C048, **C060, **C072
**H036, **H048, **H060, **H072
These instructions should be used only as a supplement to the
installation instructions provided with the above units.
EHK
ELECTRIC HEAT KITS
INSTALLATION INSTRUCTIONS
© 2013
5151 San Felipe, Suite 500, Houston, TX 77056
www.daikincomfort.com
P/N: IOD-7014 Date: July 2013