DX13S Commercial 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner Cooling Capacity: 36,000 - 60,000 BTU/h ■ Contents Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data.......................... 4 AHRI Ratings ........................................ 16 Dimensions........................................... 19 Wiring Diagrams .................................. 20 Accessories...........................................
Nomenclature D X 13 S A 036 3 A A 1 2 3,4 5 6 7,8,9 10 11 12 Brand D -‐ Daikin Engineering Minor revision Type X -‐ AC R-‐410A Z -‐ HP R-‐410A Engineering Major revision Voltage 3 -‐ 208/230 V Three-‐Phase 60 Hz EER 4 -‐ 460 V Three-‐Phase 60 Hz 13 -‐13 SEER Compressor S -‐ Single Stage Tonnage Nominal 036 -‐ 3 tons 048 -‐ 4 tons 060 -‐ 5 tons Featur
Product Specifications DX13SA 0363A* DX13SA 0364A* DX13SA 0483A* DX13SA 0484A* DX13SA 0603A* DX13SA 0604A* Cooling Capacities 36,000 36,000 48,000 48,000 60,000 60,000 SEER Nominal Cooling (BTU/h) 13 13 13 13 13 13 Decibels 74 74 76 76 72 72 10.4/73 5.8/38.0 13.1/83.1 6.1/41 16/110 7.8/52 Scroll Scroll Scroll Scroll Scroll Scroll Horsepower 1/6 1/6 1/4 1/4 1/4 1/4 FLA 1.1 0.6 1.2 0.8 1.3 0.8 Liquid Line Size (“O.D.
www.daikinac.com 59 31.1 0.70 19 2.42 6.1 224 103 33.7 0.72 19 2.48 6.3 231 106 34.7 0.76 18 2.50 6.3 234 107 31.6 0.79 22 2.44 6.2 227 104 34.2 0.82 22 2.50 6.3 234 107 35.3 0.86 21 2.52 6.4 236 108 Airflow MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR 32.5 0.71 20 2.49 6.3 244 111 35.3 0.73 20 2.55 6.5 252 114 36.3 0.77 19 2.57 6.
SS-DX13SC www.daikinac.com 63 32.9 0.81 23 2.51 6.4 246 112 35.6 0.84 23 2.57 6.5 254 115 36.7 0.88 22 2.59 6.6 257 116 33.4 0.88 26 2.53 6.4 249 113 36.2 0.91 25 2.59 6.6 257 116 37.2 0.95 24 2.61 6.7 259 117 59 32.2 0.87 24 2.46 6.2 229 105 34.9 0.90 24 2.52 6.4 236 108 35.9 0.94 23 2.54 6.4 238 109 MBh 32.7 S/T 0.91 ∆T 26 2.48 1050 kW Amps 6.3 HI PR 231 LO PR 106 MBh 35.5 S/T 0.94 ∆T 26 1200 kW 2.54 Amps 6.4 HI PR 238 LO PR 109 MBh 36.5 S/T 0.99 ∆T 25 2.55 1350 kW Amps 6.
www.daikinac.com 59 31.1 0.70 19 2.42 6.1 224 103 33.7 0.72 19 2.48 6.3 231 106 34.7 0.76 18 2.50 6.3 234 107 31.6 0.79 22 2.44 6.2 227 104 34.2 0.82 22 2.50 6.3 234 107 35.3 0.86 21 2.52 6.4 236 108 Airflow MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR 32.5 0.71 20 2.49 6.3 244 111 35.3 0.73 20 2.55 6.5 252 114 36.3 0.77 19 2.57 6.
SS-DX13SC www.daikinac.com 63 32.9 0.81 23 2.51 6.4 246 112 35.6 0.84 23 2.57 6.5 254 115 36.7 0.88 22 2.59 6.6 257 116 33.4 0.88 26 2.53 6.4 249 113 36.2 0.91 25 2.59 6.6 257 116 37.2 0.95 24 2.61 6.7 259 117 59 32.2 0.87 24 2.46 6.2 229 105 34.9 0.90 24 2.52 6.4 236 108 35.9 0.94 23 2.54 6.4 238 109 MBh 32.7 S/T 0.91 ∆T 26 2.48 1050 kW Amps 6.3 HI PR 231 LO PR 106 MBh 35.5 S/T 0.94 ∆T 26 1200 kW 2.54 Amps 6.4 HI PR 238 LO PR 109 MBh 36.5 S/T 0.99 ∆T 25 2.55 1350 kW Amps 6.
www.daikinac.com 59 40.4 0.71 19 3.15 6.9 219 104 43.8 0.73 18 3.22 7.0 225 108 45.1 0.77 18 3.24 7.1 228 109 41.1 0.81 22 3.17 6.9 221 105 44.5 0.84 21 3.24 7.1 228 109 45.8 0.88 21 3.27 7.2 230 110 Airflow MBh S/T ∆T kW 1400 Amps HI PR LO PR MBh S/T ∆T kW 1600 Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T kW 1400 Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T kW 1800 Amps HI PR LO PR 42.3 0.72 20 3.23 7.1 238 112 45.8 0.75 20 3.30 7.2 245 116 47.2 0.78 19 3.33 7.
SS-DX13SC www.daikinac.com 63 42.7 0.83 23 3.26 7.1 240 113 46.3 0.86 23 3.33 7.3 248 117 47.7 0.90 22 3.35 7.4 250 118 43.4 0.89 25 3.28 7.2 243 114 47.0 0.93 25 3.35 7.4 250 118 48.4 0.97 24 3.38 7.4 253 119 59 41.8 0.88 24 3.20 7.0 223 106 45.3 0.92 24 3.27 7.2 230 110 46.7 0.96 23 3.29 7.2 232 111 MBh 42.5 S/T 0.93 ∆T 26 kW 3.22 1400 Amps 7.0 HI PR 225 LO PR 108 MBh 46.1 S/T 0.96 ∆T 25 1600 kW 3.29 Amps 7.2 HI PR 232 LO PR 111 MBh 47.5 S/T 1.00 ∆T 24 kW 3.31 1800 Amps 7.
www.daikinac.com 59 40.4 0.71 19 3.15 3.7 219 104 43.8 0.73 18 3.22 3.8 225 108 45.1 0.77 18 3.24 3.9 228 109 41.1 0.81 22 3.17 3.8 221 105 44.5 0.84 21 3.24 3.9 228 109 45.8 0.88 21 3.26 3.9 230 110 Airflow MBh S/T ∆T kW 1400 Amps HI PR LO PR MBh S/T ∆T kW 1600 Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T kW 1400 Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T kW 1800 Amps HI PR LO PR 42.3 0.72 20 3.23 3.8 238 112 45.8 0.75 20 3.30 3.9 245 116 47.2 0.78 19 3.
SS-DX13SC www.daikinac.com 63 42.7 0.83 23 3.25 3.9 240 113 46.3 0.86 23 3.33 4.0 248 117 47.7 0.90 22 3.35 4.0 250 118 43.4 0.89 25 3.28 3.9 243 114 47.0 0.93 25 3.35 4.0 250 118 48.4 0.97 24 3.38 4.0 253 119 59 41.8 0.88 24 3.19 3.8 223 106 45.3 0.92 24 3.26 3.9 230 110 46.7 0.96 23 3.29 3.9 232 111 MBh 42.5 S/T 0.93 ∆T 26 kW 3.22 1400 Amps 3.8 HI PR 225 LO PR 108 MBh 46.1 S/T 0.96 ∆T 25 1600 kW 3.29 Amps 3.9 HI PR 232 LO PR 111 MBh 47.5 S/T 1.00 ∆T 24 kW 3.31 1800 Amps 3.
www.daikinac.com 59 53.8 0.66 22 3.97 15.4 228 98 55.4 0.69 20 4.00 15.5 230 99 55.6 0.70 18 4.03 15.7 233 100 54.7 0.75 25 4.00 15.5 230 99 56.3 0.78 23 4.03 15.7 233 100 56.6 0.79 21 4.06 15.8 235 101 Airflow MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR 56.3 0.67 23 4.09 15.9 248 105 58.0 0.70 21 4.12 16.1 250 106 58.3 0.
SS-DX13SC www.daikinac.com 63 56.9 0.77 27 4.12 16.1 250 106 58.6 0.80 25 4.15 16.2 253 107 58.8 0.82 22 4.19 16.4 255 108 57.7 0.83 29 4.15 16.2 253 107 59.4 0.87 27 4.19 16.4 255 108 59.7 0.88 24 4.22 16.5 258 109 59 55.6 0.82 28 4.03 15.7 233 100 57.3 0.86 26 4.07 15.8 235 101 57.6 0.87 23 4.10 16.0 237 102 MBh 56.6 S/T 0.86 ∆T 30 4.07 1500 kW Amps 15.8 HI PR 235 LO PR 101 MBh 58.3 S/T 0.90 ∆T 28 1750 kW 4.10 Amps 16.0 HI PR 237 LO PR 102 MBh 58.6 S/T 0.91 ∆T 25 4.13 2000 kW Amps 16.
www.daikinac.com 59 53.8 0.66 22 3.97 15.4 228 98 55.4 0.69 20 4.00 15.5 230 99 55.6 0.70 18 4.03 15.7 233 100 54.7 0.75 25 4.00 15.5 230 99 56.3 0.78 23 4.03 15.7 233 100 56.6 0.79 21 4.06 15.8 235 101 Airflow MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR 56.3 0.67 23 4.09 15.9 248 105 58.0 0.70 21 4.12 16.1 250 106 58.3 0.
SS-DX13SC www.daikinac.com 63 56.9 0.77 27 4.12 16.1 250 106 58.6 0.80 25 4.15 16.2 253 107 58.8 0.82 22 4.19 16.4 255 108 57.7 0.83 29 4.15 16.2 253 107 59.4 0.87 27 4.19 16.4 255 108 59.7 0.88 24 4.22 16.5 258 109 59 55.6 0.82 28 4.03 15.7 233 100 57.3 0.86 26 4.07 15.8 235 101 57.6 0.87 23 4.10 16.0 237 102 MBh 56.6 S/T 0.86 ∆T 30 4.07 1500 kW Amps 15.8 HI PR 235 LO PR 101 MBh 58.3 S/T 0.90 ∆T 28 1750 kW 4.10 Amps 16.0 HI PR 237 LO PR 102 MBh 58.6 S/T 0.91 ∆T 25 4.13 2000 kW Amps 16.
AHRI Ratings Outdoor Unit DX13SA 0363A* DX13SA 0364A* 16 Indoor Units Cooling Ratings CFM AHRI # 11.0 1,175 6334369 11.3 1,200 6334370 13.0 11.0 1,020 6334373 13.0 11.0 1,275 6334374 25,600 13.0 11.0 1,050 7988968 25,800 13.0 11.0 1,175 6334375 34,200 25,800 13.0 11.0 1,175 6334376 34,000 25,600 13.8 11.8 1,210 6334377 ASPT42D14A* 34,600 26,000 14.0 12.0 1,280 6334378 AWUF36XX16B* 33,400 25,200 13.0 11.
AHRI Ratings Outdoor Unit DX13SA 0483A* DX13SA 0484A* Indoor Units AHRI # 11.0 1,475 6334394 11.0 1,500 6334395 13.0 11.0 1,550 6334396 13.0 11.0 1,550 6334397 34,600 13.0 11.0 1,455 8171750 34,200 13.0 11.0 1,460 6334398 44,500 34,200 13.0 11.0 1,460 6334399 46,000 35,200 13.8 11.3 1,600 6334400 ASPT60D14A* 46,000 35,200 13.8 11.3 1,600 6334401 CA*F4860*6D*+EEP 46,000 35,200 13.0 11.0 1,600 6334404 CA*F4860*6D*+MBVC2000**-1A* 46,000 35,200 14.
AHRI Ratings DX13SA 0604A* ARPT48D14A* 54,500 37,400 13.0 11.0 1,500 6334443 ARPT60D14A* 55,000 37,600 13.0 11.0 1,500 6334444 ARUF48D14A* 54,500 37,400 13.0 11.0 1,500 6334445 ARUF60D14A* 55,000 37,600 13.0 11.0 1,500 6334446 CA*F4860*6D*+EEP 55,000 37,600 13.0 11.0 1,500 6334448 CA*F4860*6D*+MBVC2000**-1A* 56,000 38,500 13.5 11.5 1,575 6334449 CA*F4860*6D*+MBVC2000**-1A*+TXV 56,000 38,500 14.0 11.5 1,575 6334450 CA*F4961*6D*+EEP 56,500 38,500 13.0 11.
Dimensions W D H Model SS-DX13SC www.daikinac.
www.daikinac.com IO CM AUX MAIN BK BR PU T1 BK COMP T2 L2 L1 T3 RD L3 T3 T2 C YL BK RD T1 BK Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. YL YL BL CONTROL BOX ⚠ PU RD BR LVJB NOTE 1 C T1 C CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
SS-DX13SC www.daikinac.com IO CM AUX MAIN T1 BK T1 C L2 COMP T2 L1 T2 T3 PU RD ⚠ RD L3 T3 BK RD BK YL Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. BK BR PU YL YL BL CONTROL BOX FC BR WARNING LVJB NOTE 1 C T1 CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
Accessories Model # Description DX13SA 0363** DX13SA 0364** DX13SA 0483** DX13SA 0484* DX13SA 0603** DX13SA 0604** ABK-20 Anchor Bracket Kit ^ x x x x x x ASC-01 Anti-Short Cycle Kit x x x x x x FSK01A¹ Freeze Protection Kit ² x x x x x x LSK01A² Liquid Line Solenoid Kit x x x x x x LAKT01 Low Ambient Kit x x x x x x 0163R00002 Crankcase heater x 0163R00003 Crankcase heater 0163R00004 Crankcase Heater 0163R00031 Crankcase Heater OY18-60A Outdoor The
Notes SS-DX13SC www.daikinac.
Notes Our continuing commitment to quality products may mean a change in specifications without notice. © 2018 • Houston, Texas • Printed in the USA. 24 www.daikinac.