PRODUCT REGISTRATION Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed power protection, operation, and performance during the lifetime of the product. Please take a few minutes to register your product at: www.CyberPowerSystems.com/registration. Registration certifes your product’s warranty, confrms your ownership in the event of a product loss or theft, and entitles you to free technical support.
INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt. The box should contain the following: (a) UPS unit (b) User’s manual (c) USB device cable PowerPanel® software is available on our website. Please visit www.cyberpowersystems.com and go to the Software Section for a free download. supplied outlets. Plug the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets.
SYSTEM FUNCTION BLOCK DIAGRAM Input EMI Filter Surge Suppressor Normal Mode Battery Mode Output AVR Charger AC / DC Inverter Battery BASIC OPERATION 1. Battery and Surge Protected Outlets The unit has six battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure.
BASIC OPERATION - continued 8. LCD module display (LE1000DG) LCD display shows all the UPS information using icons and messages. For more information please review the “Defnitions for Illuminated LCD Indicators” section. 9. USB Port The USB port allows connection and communication between the USB port on the computer and the UPS unit. 10. Communication Protection Ports Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11) 11.
TROUBLESHOOTING Problem Full-time surge protection outlets stop providing power to equipment. Circuit breaker button is projecting from the side of the unit. Possible Cause Circuit breaker has been tripped due to an overload. Turn the UPS of and unplug at least one piece of equipment. Reset the circuit breaker by depressing the button, and then turn the UPS on. Battery not fully charged. Recharge the battery by leaving the UPS plugged in. Battery is worn out.
DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS i CONDITION POWER FAULT (LE850G) ALARM On Of Of Normal On* Of Beep twice every 30 seconds Utility Failure - The UPS is providing power to battery power-supplied outlets from its battery. On* Of Rapid beeping every 1/2 second Utility Failure - The UPS is providing battery power.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS - continued LOAD CAPACITY Meter: This meter displays the approximate output load level of the UPS battery outlets in 20% increments. equipment from battery outlets and turn the UPS on again.) E21: Battery Output Short fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.) FAULT: The following number appears if there is a problem with the UPS. Press the POWER button to turn the UPS of.