XTi2 Series Operation Manual XTi 1002 XTi 2002 XTi 4002 XTi 6002 Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of design, production, or variations of the equipment.
XTi2 Series Power Amplifiers Important Safety Instructions 1. Read these instructions. WATCH FOR THESE SYMBOLS: 2. Keep these instructions. The lightning bolt triangle is used to alert the user to the risk of electric shock. 3. Heed all warnings. 4. Follow all instructions. The exclamation point triangle is used to alert the user to important operating or maintenance instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings.
XTi2 Series Power Amplifiers DECLARATION OF CONFORMITY Issued By: Harman International. 1718 W. Mishawaka Rd. Elkhart, IN 46517 U.S.A. FOR FIELD SERVICE QUESTIONS CALL: 1 800 342 6939 European Representative’s Name and Address: David J.
XTi2 Series Power Amplifiers Get Started Stereo DSP Off This is the default mode the amplifier is set to from the factory. The amplifier is configured for stereo mode with all processing disabled. 1. Connect Left/Right signal source to Channel 1 and Channel 2 using the XLR connectors. 2. Connect a speaker to each channel output using Speakon®, Banana Plugs, or bare wire. XTi 6002 back panel shown.
XTi2 Series Power Amplifiers Get Started Factory Preset #3: XOVER Putting the amplifier in XOVER mode enables a 1.2kHz 4th order (24dB/octave) filter that sends frequencies of 1.2kHz and below to Channel 1 output and frequencies of 1.2kHz and above to Channel 2 output. The XTi2 Series amplifiers come pre-loaded with a preset that makes it easy to configure the amplifier for this operation. HIGH 2+/– LOW 1+/– Before you get started ensure that you: 1.
XTi2 Series Power Amplifiers Get Started Factory Preset #5: SUBSYNTH Putting the amplifier in SUBSYNTH mode allows you to turn on the SubHarmonic Synth feature for use with a subwoofer on both channels. The inputs are automatically summed, a 90Hz 4th order (24dB/octave) filter is enabled on both Channel 1 and Channel 2, and the SubHarmonic Synth feature is turned on at +12dB level. The XTi2 Series amplifiers come pre-loaded with a preset that makes it easy to configure the amplifier for this operation.
XTi2 Series Power Amplifiers Welcome There’s no debate – when you choose Crown’s XTi2 Series, you’re choosing one of the most powerful and innovative amplifiers on the market today. That’s because the all-new XTi2 Series amps continue to set the standard for unmatched performance and value, delivering the goods night after night without breaking a sweat.
XTi2 Series Power Amplifiers Front Panel Features Indicators: Ready Indicator: Two green LEDs, one for each channel, illuminate when the amplifier is ready to produce audio. Signal Presence Indicator: Two green LEDs, one for each channel, illuminate when the channel input exceeds -40dBu. Useful for troubleshooting cable runs. -20 Indicator: Two green LEDs, one for each channel, illuminate when the output signal exceeds -20dB below clip.
XTi2 Series Power Amplifiers Back Panel Features XTi 1002, 2002, 4002 Binding Post Output Jacks: Power Cord Clip: Mounting points for securing, included power cord clip. One pair per channel, accepts banana plugs or bare wire. Note: Binding Post outputs on European models come with safety plugs installed to prevent European power plugs from being inserted. The side entry positions for these connectors should be used with European models.
XTi2 Series Power Amplifiers Front Panel Navigation From the front panel, you can change settings for several of the amplifier’s integrated signal processing features: Input Y, Crossover Frequency, EQ, Delay, Limiting, and Stereo/Bridge-Mono. The Icons in the display illuminate to show which features are currently applied and turned on. When you power-on the amplifier for the first time, the LCD screen displays “DSP OFF” (no DSP is applied).
XTi2 Series Power Amplifiers Integrated Processing Features The XTi2 Series amplifiers include a number of integrated processing features which appear as icons on the front panel LCD screen. They are described below: NOTE: System Architect Software is required to have full control over all Integrated Processing Features which can be downloaded from the following URL – http://hiqnet.harmanpro.com/. When controlling more than one XTi2 at a time you will need USB Hub. We recommend using a Powered USB Hub.
XTi2 Series Power Amplifiers Integrated Processing Features Advanced Thermal Control In this section, you can tailor the fan speed to specific applications. You have the choice of the following modes: t /PSNBM t &BSMZ t 'VMM 4QFFE The fan mode can be changed using the front panel buttons at start-up or in the software. The default mode is normal and should work fine for most applications. Early mode turns the fan on sooner at a “lower” temperature, and Full-speed mode turns the fan on full-speed full-time.
XTi2 Series Power Amplifiers XTi2 Specifications Minimum Guaranteed Power, 1 kHz XTi 1002 XTi 2002 XTi 4002 XTi 6002 Per channel, both channels driven Stereo, 2 ohms (per channel) 700W *† Stereo, 4 ohms (per channel) Stereo, 8 ohms (per channel) 1,000W * 1,600W * 3,000W * 500W 800W 1,200W 2,100W 275W 475W 650W 1,200W 2,000W * 3,200W * 6,000W * 1,600W 2,400W 4,200W Bridge-Mono, 4 ohms 1,400W Bridge-Mono, 8 ohms 1,000W *† With 0.5% THD. *With 1% THD.
XTi2 Series Power Amplifiers Service Crown amplifiers are quality units that rarely require servicing. Before returning your unit for servicing, please contact Crown Technical Support to verify the need for servicing. Warranty is only valid within the country in which the product was purchased. This unit has very sophisticated circuitry which should only be serviced by a fully trained technician.
XTi2 Series Power Amplifiers Service 3. Ship product to: CROWN AUDIO FACTORY SERVICE 1718 W MISHAWKA RD. ELKHART, IN 46517 4. Use a bold black marker and write the SRA number on three sides of the box. 5. Record the SRA number for future reference. The SRA number can be used to check the repair status. Packing Instructions Important: These instructions must be followed. If they are not followed, Crown Audio, Inc. assumes no responsibility for damaged goods and/or accessories that are sent with your unit.
XTi2 Series Power Amplifiers Warranty — UNITED STATES & CANADA SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship.
XTi2 Series Power Amplifiers Warranty — WORLDWIDE EXCEPT USA & CANADA SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A.
XTi2 Series Power Amplifiers THIS PAGE INTENTIONALLY LEFT BLANK page 48 Operation Manual
XTi2 Series Power Amplifiers PRODUCT REGISTRATION Crown Audio, Inc. 1718 W. Mishawaka Rd. Elkhart, IN 46517-9439 Phone: 574-294-8000 Fax: 574-294-8329 www.crownaudio.com Online registration is also available at http://crownweb.crownintl.com/webregistration. Warranty is only valid within the country in which the product is purchased. When this form is used to register your product, it may be mailed or faxed. Crown Audio, Inc.
XTi2 Series Power Amplifiers THIS PAGE INTENTIONALLY LEFT BLANK page 50 Operation Manual
XTi2 Series Power Amplifiers Crown Audio Factory Service Information Shipping Address: Crown Audio Factory Service, 1718 W. Mishawaka Rd., Elkhart, IN 46517 PLEASE PRINT CLEARLY SRA #: ______________________ (If sending product to Crown factory service.
XTi 1002 XTi 2002 You also have greatly improved control capabilities. The addition of Peakx Plus™ Limiters gives you full command over threshold, attack and release, and we enhanced the Subharmonic Synth so you can easily manage frequency, gain and filter type, allowing for application-specific tuning. Plus, you’ll now be able to tailor fan speed for specific applications and have software visibility of the Power Supply Temperature and AC Line Voltage.
PERF PE RFOR RF ORMA OR MANC MA NCEE NC CON ONTTRO ROLS LS Sensitivity (for full rated power at 4 ohms): 1.4 Vrms Level: Two front-panel rotary level controls, one for each channel. Frequency Response BU ƴ XBUU ƵƳ )[ UP ƵƳ L)[ ƲƳ E# Džƴ E# Power Switch: 0O 0Ƌ TXJUDI BQQMJFT "$ QPXFS to the amplifier.
CROWN WARRANTY EXTENSION TO 6-YEARS 2020 Sales Promotion Effective January 1, 2020, all Crown finished goods sold by Harman Professional will automatically receive a warranty extension to 6 years. Applicability Warranty Policy • All Crown finished goods sold between January 1, 2020 – December 31, 2020 • Default warranty policy durations will remain unchanged.