Operating Guide

18
No AC output.
1. Generator is overloaded.
2. Inverter module is overheated.
3. Short circuit in electrical device.
4. Faulty inverter assembly.
1. Disconnect all loads. Shut down gen-
erator to reset module. Reduce loads,
r
e
start generator.
2. Verify service door is ON. Let cool 15
minut
es b
y running engine without
AC output. Press and hold Reset but-
ton on control panel, restart generator.
3. Verify condition of extension cords
an
d
items being powered. Press and
hold Reset button on control panel.
4. Contact Customer Service at 1-888-
331-4569.
Fuel leaks from drain hoses.
1. Carburetor drain in bowl is not closed. 1. Turn valve clockwise to close.
* Engine speed increases and decreases — This is normal as generator starts up and loads vary.
PROBLEM CAUSE CORRECTION