SD2500 Specifications

2500W (de-rating after 40°C, refer to de-rating curve)
SD2500-212 SD2500-224 SD2500-248SD2500-112 SD2500-124 SD2500-148
90%88%88%90%89%
40.0~64.0VDC
48VDC
@48VDC
20.0~32.0VDC
24VDC
@24VDC
12VDC
10.0~16.0VDC
@12VDC
48VDC24VDC
40.0~64.0VDC
20.0~32.0VDC
10.0~16.0VDC
@48VDC
@24VDC
< 1A
< 1.8A
< 3.6A< 0.8A
< 1.4A
< 2.9A
Pure Sine Wave
100 / 110 / 115 / 120VAC ±3% 200 / 220 / 230 / 240VAC 3%±
50 / 60Hz ±0.1%
< 3% @ under condition : greater than 1.15 times
of the rated VDC, 110V / linear load)
2500W Pure Sine Wave
SD2500 series
Parallel redundancy design for power expansion
Automatic master mechanism to eliminate single point
failure and optimize reliability
Built-in ATS and AC circuit breaker
RS-232 communication
Input & output fully isolation
Output voltage / power saving mode selectable by DIP switch or
remote control (CR-10)
Input Protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage
Output Protection: Short Circuit / Overload / Over Temperature /
Over Voltage
Features:
Optional STS module, transfer time less 4ms.
0.4A
0.7A
1.1A
0.3A
0.35A
0.9A
Multiple industrial applications that create 1 W / 3 4W power systems Ф3 Ф
15Ax620Ax9 15Ax620Ax940Ax9
100 / 110 / 115 / 120VAC 12.5%± 200 / 220 / 230 / 240VAC 12.5%±
47 - 57 / 53 - 63 Hz
20A
Optional STS module : <4ms
Standard ATS : Inverter to utility AC:8~10ms.; Utility AC to inverter: 16~50ms.
Load & Thermal control fan
283x128x436 mm / 11.14x5.04x17.17 inch
RS-232 (RJ-11 type connector), Ethernet (optional)
Max. 90%, non-condersing
-40 ~ +70°C
Reverse Polarity (Fuse) / Under Voltage / Over Voltage Protection / AC over current (Breaker)
Short Circuit / Overload / Over Temperature / Over Voltage
50.0VDC
62.0VDC
64.0VDC
25.0VDC
31.0VDC
32.0VDC
30.0VDC
12.5VDC
15.5VDC
16.0VDC
15.0VDC
50.0VDC
62.0VDC
64.0VDC
60.0VDC
25.0VDC
31.0VDC
32.0VDC
30.0VDC
40.0VDC20.0VDC10.0VDC40.0VDC20.0VDC
42.0VDC10.5VDC42.0VDC21.0VDC
-20 ~ +60°C; refer to SD2500 power de-rating curve
Input voltage level, faulty status
CR-6, CR-8 and CR-10
Certified EN60950-1
* UL 458Certified
Certified FCC Class B
**Certified EN 55014-1,
EN 61000-3-2, 3-3, EN61204-3;
EN 55014-2,
EN 61000-6-1, -6-2, -6-3, -6-4
21.0VDC
60.0VDC
Rating Power
Efficiency (Max.)
DC Voltage
Voltage Range
No load Power Consumption
Waveform
Output Frequency
Output Voltage (@rated VDC)
Total Harmonic Distortion (THD)
Peak Power (3Sec.)
Surge Power (<0.2Sec.)
On Mode @ No Load Mode
On Mode @ Save Mode
AC Range
Frequency Selectable
Synchronous Frequency
Circuit Breaker
Transfer Switch ***
Cooling
Weight
Dimension (WxHxD)
Communication Port
Relative Humidity
Working Temp.
Storage Temp.
BAT.High Alarm ±3%
BAT.High Restart ±3%
BAT.Low Restart ±3%
BAT.High Shut-down ±3%
Input Protection
Output Protection
BAT.Low Shut-down ±3%
BAT.Low Alarm ±3%
LED Indicator
Remote control
Safety Standards
EMC Standards
Output
DC Input
Fuse
Others
Environment
Protection
Control & Signal
Safety & EMC
AC Input
MODEL
3000W
4000W
88%
12VDC
@12VDC
40Ax9
50 / 60 Hz
35A
12.5VDC
15.5VDC
16.0VDC
15.0VDC
10.0VDC
10.5VDC
8 kg
< 3% @ under condition : greater than 1.15 times
of the rated VDC, 230V / linear load)
Note
*UL-458 only support 112 and 124 model.
**EN55014-1, EN55014-2 Class B : output cable less than 2 meters.
***Please refer to Transfer - Time Table.
Certified CISPR 25; ISO11452-2; ISO 7637-2
E-Mark
REV. A2