Installation Guide

33
This appliance shall be installed only by authorized persons and in
accordance with the manufacturer's installation instructions, local gas fitting
regulations, municipal building codes, electrical wiring regulations, local
water supply regulations.
This range is factory-set for use with Natural gas. To use this range with
Propane gas, see the "GAS CONVERSION section before connecting this range
to the gas supply. Gas conversions from Natural gas to Propane gas or from
Propane gas to Natural gas must be done by a qualified installer.
TYPICAL FLEXIBLE CONNECTION
b
c
e
a
d
d
Adapter (provided)
Gas Pressure Regulator
Gas Supply Line
Adapters (From Gas
Supply Line Kit)
Gas Shutoff Valve
b
a
c
d
e
1. Apply pipe-joint compound made for use with LP gas to the smaller
thread ends of the flexible connector adapters.
2. Attach one adapter to the gas pressure regulator and the other adapter
to the gas shutoff valve. Tighten both adapters, being certain not to
move or turn the gas pressure regulator.
3. Use a 15/16" (2.4 cm) combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that connector is not
kinked.