User Manual of Infrared Forehead Thermometer Model: IR-FT Comper Chuangxiang(Beijing)Technology Co.
Table of Contents 1.Information on registrant/manufacturer ................................................................................................................... 3 2.Product introduction ................................................................................................................................................. 4 3.Intended use: ....................................................................................................................................................
1. Information on registrant/manufacturer Name of registrant: Comper Chuangxiang(Beijing)Technology Co., Ltd Address of registrant: 102,103 - F1, Room 203,213 - F2, Building 4, No. 1 Kangding Street, Beijing Economic-Technological Development Area, Beijing Contact information of registrant: +86 10-57480968 Name of manufacturer: Comper Chuangxiang(Beijing)Technology Co., Ltd Address of manufacturer: 102,103 - F1, Room 203,213 - F2, Building 4, No.
2. Product introduction This Forehead Thermometer takes the body temperature by measuring the infrared energy emitted from the forehead skin above the eyebrows. The Forehead Thermometer adopts gentle-touch, user friendly and non-invasive measurement design. It instantly displays the accurate reading of the body temperature with just a gentle forehead touch. 3.
2. Mount the positive and negative poles of batteries correctly. Replace the dying batteries in time to avoid overheat, fluid leakage and damage of the batteries, which may further damage the device. 3. Do not attempt to repair the product by yourself. In case of any quality issue or any doubt about the measurement accuracy of thermometer, please contact the dealer or the manufacturer. 4. Please dispose of the replaced components (e.g.
Four short beeps are emitted to signal low battery when the actual supply voltage of the product is ≤ 2.51 V. Three short beeps are emitted to signal low environment temperature: When the temperature is lower than 10±1℃ (50±1℉); Three short beeps are emitted to signal high environment temperature: When the temperature is higher than 40±1℃ (104±1 ℉). A prompt message will appear after batteries are installed and device starts up; A “beep” is emitted to indicate that the measurement is completed.
- Check to make sure the batteries have enough power. - The packaged product can be transported via common vehicles. However, it is necessary to prevent the product from rain, damp, extrusion and mechanical collision. 2) Unpacking: Open the individual-packed color box, take out the package with Forehead Thermometer and remove the Forehead Thermometer from the plastic tray. 3) Battery installation or replacement - Open the battery cover and replace the batteries.
emissivity. The default emissivity of this product is 1.0. The measured temperature will deviate from the actual value for different emissivities. 4) Operation procedures 4.1 Measurement - Power On/Off: In the Off state, lightly press the “Power/Temperature Measurement Button” for to start up. The device will start self-inspection and the LED screen will be fully on. It will be ready for measurement after the self-inspection.
After 1 min of inactivity, the Forehead Thermometer will automatically shut down. 1. Be sure to read the IFU carefully prior to use. 2. The ambient temperature applicable to this product is 10℃ (50℉)to 40℃ (104℉), where 25℃ (77℉) is optimal. Precautions 3. Please do not take this product too close to a charged object to avoid electric shock. 4. Please do not use this product in an environment with a relative humidity greater than 95%. 5.
In body temperature mode, if the measured temperature is higher than 43.0℃ (109.4℉) High temperature warning Err Error prompt When the ambient temperature range is beyond 10℃~40℃ (50℉-104℉) ErrH Hardware fault ErrE Storage hardware fault 7. Contraindications, precautions, warnings and prompts 1) Contraindications Currently none 2) Precautions - The product is an infrared forehead thermometer for professional measurement of body temperature.
● It may lead to illness exacerbation. If the device is to be left idle for a long time (over 3 months), remove the batteries and keep out of the reach of children. ● Otherwise, it may cause ingestion by children. Keep the product out of the reach of children. At the same time, please prevent the children from using the device alone. ● Otherwise, it may cause injury to children or damage to the equipment. Please dispose of the used-up batteries according to the local requirements.
● Places with high temperature, moist, direct sunlight exposure, dust and being salty. ● If the product is to be left idle for a long time (over 3 months), please remove the batteries for safekeeping. 3) About safekeeping ● When not in use, store it in a locker/box. 4) Maintenance period ● The product shall be cleaned and maintained after each use. Product repair Do not repair the product by yourself.
Type BF applied part Keep dry Low battery prompt Avoid sunlight Straight up Fragile; Handle with care Discarded electronic or electrical equipment Radio transmitting equipment Serial number Date of manufacture Manufacturer 11. Troubleshooting Failure/issue Higher measurement result Lower measurement result Possible cause Measures that can be taken Make measurement immediately after taking the forehead thermometer into a room under normal temperature when it is stored in a cold environment.
measurement. 12. Clinical accuracy: The normal body temperatures are within a certain range. The body temperatures measured at different sites will be different. See the specific differences in the following table: Measurement site Normal body temperature Forehead temperature 34.7℃~37.8℃ (94.5℉-100℉) Deviation 0.3℃~0.5℃ (0.5-0.9℉) lower than the oral temperature The product is applicable to people of all ages. The body temperatures of different groups will be different.
When a low battery prompt symbol appears on the display screen, please replace with dedicated batteries. Battery mounting and replacement should follow Part 3 "Battery mounting and replacement methods" in "Correct application methods" of the Instructions for Use. 15. Thermometer modes Comper Smart Infrared Forehead Thermometer has the measurement mode and calibration mode.
only for its internal function. Therefore, RF emissions are very low and are not likely to cause any interference to nearby electronic equipment.
a typical location in a typical commercial or hospital environment. IEC61000-4-8 Note: UT is the a.c. mains voltage prior to application of the test voltage. Table 3: Electromagnetic immunity 2 Guidance and manufacturer's statement - Electromagnetic immunity IR-FT Infrared Forehead Thermometer is intended for use in the electromagnetic environment as specified below.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment of fixed RF transmitters, an electromagnetic site survey shall be considered.
Warranty Information From the date of purchasing the equipment, you can enjoy the following after-sales services provided by comper with the purchase invoice: One-year Warranty. Warranty principle: 1. Free warranty for products with host quality issues within one year; 2. Please deliver the product to the address of after-sales service unit of comper for repair. 3. The issues arising from battery leakage, repair and disassembly on one's own, man-made damage, natural disasters and force majeure, etc.
Federal Communications Commission (FCC) Statement 1) This device may not cause harmful interference and 2) This device must accept any interference received, including interference that may cause undesired operation. 15.21 Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.
Copyright Statement The copyright is reserved by Comper Chuangxiang(Beijing)Technology Co., Ltd, which enjoys and retains all the exclusive rights of copyright according to law. No part of this document may be modified, excerpted, reproduced, or otherwise, in any form without prior written permission of the company. Regarding the contents of this document, the company assumes no express or implied warranties or guarantees.