Quick Start Guide

QSG_RLGE2FE16R_REV– 3 Aug 2016 PAGE 10
QUICK START GUIDE RLGE2FE16R
TECH SUPPORT: 1.888.678.9427
Management over Console
Connecting to Device
» Device is capable of being first set up via either the console port, or via an SSH connection
» Default Username: su
» Default Password: 1234
» By default all ports act as a flat switch, with all ports as members of VLAN 1
» VLAN 1 set to hold an IP interface by default
» Default Management IP: 10.0.0.1/8
Terminal
» Power on device (Boot may take up to 3 minutes). PWR light should be green
» Console into Device
Connect to CON port using white ComNet Console Cable. Other console cables will not
work as they have a different pinout.
Connect to to serial port of PC, or use Serial to USB cable. (Drivers may need to be installed)
Terminal Serial Connection
1. Install and open terminal software
2. Setup terminal for serial session
3. Determine correct COM port on PC (Device manager)
4. Enter correct COM port, enter correct baud rate speed (Default 9600)
5. Click Open to start session with device
Press enter if screen is blank
Default login username su, password 1234 (password will be invisible)