Installation Manual

INS_CWGE26FX2TX24MSPOE_REV– 5 Mar 2014 PAGE 84
INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE
TECH SUPPORT: 1.888.678.9427
Logging Specify the logging operation of the ACE. The allowed values are:
Enabled: Frames matching the ACE are stored in the System Log.
Disabled: Frames matching the ACE are not logged.
Please note that the System Log memory size and logging rate is limited.
Shutdown Specify the port shut down operation of the ACE. The allowed values are:
Enabled: If a frame matches the ACE, the ingress port will be disabled.
Disabled: Port shut down is disabled for the ACE.
Counter The counter indicates the number of times the ACE was hit by a frame.
Label Description
VLAN ID Filter Specify the VLAN ID filter for this ACE.
Any: No VLAN ID filter is specified. (VLAN ID filter
status is “don’t-care”.)
Specific: If you want to filter a specific VLAN ID with
this ACE, choose this value. A field for entering a
VLAN ID number appears.
VLAN ID When “Specific” is selected for the VLAN ID filter,
you can enter a specific VLAN ID number. The
allowed range is 1 to 4095. A frame that hits this
ACE matches this VLAN ID value.
Tag Priority Specify the tag priority for this ACE. A frame that
hits this ACE matches this tag priority. The allowed
number range is 0 to 7. The value Any means that
no tag priority is specified (tag priority is “don’t-
care”.)