INS_NetWave_REV– 06/10/13 PAGE 8
IMPORTANT: Only plug PoE power to Port 1.
Connectinga PoEpowersource to the PSEPort(#2) will
cause a major device malfunction and void the warranty.
Connect one end of an RJ‐45 Ethernet cable to the LAN OUT port of the Power Injection
Module (PIM) and the other end to LAN of the access point as sown below.
Note: Maximum length of the RJ-45 CAT5 cable is 90 meters.
Connect the RJ‐45 Ethernet cable attached to the PIM to a network device, such as a switch or
to the configuration PC. Then plug the power adaptor to an AC power outlet and power plug
into the socket of the PIM as shown in the diagram below.
Note: DC Passive PoE input for the NetWave Radios is 24 - 48VDC.
A.
Connect one end of an RJ‐45 Ethernet cable to the OUT
port of the Power Injection Module (PIM) and the other end
to LAN of the access point.
Maximum length of the RJ‐45 CAT5 cable is 100 meters.*
B.
Connect the RJ‐45 Ethernet cable attached to the PIM to a
network device, such as to a switch or to the PC you will use
to configure the access point.
C.
Connect the power adaptor to the main electrical supply
and the power plug into the socket of the PIM.
PoE power input: Passive PoE (range 24 48 VDC).
The unit can also be powered by a suitable IEEE 802.3af/at
PSE device such as a PoE switch or injector. Exception: the
NWK11/M Radios only accepts Passive PoE Power.
D.
A Drip Loop is recommended as additional precaution
against moisture entering the Access Point housing.
*Up to200mW radio.Forhigher power radioupgradetohigher rating
power adapter.
Network
Edge Device
P1
P2
B
A
D
C
Ethernet
Network
D
D