4 INPUTS STANDALONE DUPLEX DIGITAL VIDEO RECORDER WITH DISPLAY ART. 80153 Please read this manual thoroughly before use and keep it for future reference. Via Don Arrigoni, 5 24020 Rovetta S. Lorenzo (Bergamo) http://www.comelit.it – E mail: export.department@comelit.
Operation Manual – Art. 80153 (Version 1.1.6) WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
Operation Manual – Art. 80153 (Version 1.1.6) FCC COMPLIANCE STATEMENT FCC INFORMATIONS: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE IN A RESIDENTIAL INSTALLATION.
Operation Manual – Art. 80153 (Version 1.1.6) IMPORTANT SAFEGUARDS 1. READ AND KEEP THESE INSTRUCTIONS Please read this manual thoroughly before use and keep it for future reference. 2. CLEANING Unplug this equipment from the wall outlet before cleaning it. Use a mild household detergent, never use strong solvent. Clean the unit with a slightly damp soft cloth. 3.
Operation Manual – Art. 80153 (Version 1.1.6) TABLE OF CONTENTS 1. INTRODUCTION ................................................................................................................ 6 2. PHYSICAL UNIT ................................................................................................................ 6 2.1. TOP PANEL..................................................................................................................... 6 2.1.1 Function Of The Top Panel...................
Operation Manual – Art. 80153 (Version 1.1.6) 5.6.5 TIME SET ............................................................................................................. 24 5.6.6 EVENT LIST ......................................................................................................... 24 5.6.7 PTZ SETUP.......................................................................................................... 25 5.6.8 F/W UPGRADE ....................................................................
Operation Manual – Art. 80153 (Version 1.1.6) 1. INTRODUCTION Art. 80153 system provides total video security solution for 4-channel digital surveillance system supporting duplex (simultaneous playback and record) functionality. Either front panel buttons or remote control unit or mouse can operate all DVR menu setting. The functionality of each button both on remote control and front panel is exactly same. 2. PHYSICAL UNIT 2.1. Top Panel 2.1.
Operation Manual – Art. 80153 (Version 1.1.6) AUDIO: “VOLUME”: 0~100. FUNCTION: Press the button “UP” or “DOWN” to change the display mode “NORMAL & ZOOM” - of the LCD monitor. “ZOOM”: 16:9; 4:3. SYSTEM: In this menu interface, users can choose the video format of display. “S-ROLOC”: AUTO; NTSC; SECAM & PAL. PRESET: In this menu interface, users can close the screen automatically in two ways. 1) Sets for the time of dormancy. The screen will be closed automatically in stipulated time.
Operation Manual – Art. 80153 (Version 1.1.6) 2.2 Front Panel A series of button on DVR front panel make a system to operate its basic functions, such as recording, playback, fast-forward, reverse, etc. For more details about the DVR menu, refer to “ 5. SETUP”. ** The front key panel feature can vary but the functionality of each button is same. ① Quad , CH1 , CH2 , CH3 , CH4 Use this button for full screen display for each camera channel or quad display on the monitor screen.
Operation Manual – Art. 80153 (Version 1.1.6) ⑦ PAUSE To pause the video playback, press the “PAUSE” button. Then the video displaying will be stopped. To continue playback, push the “PLAY” button. ⑧ MENU/ESC It displays menu option or go back to the previous. ⑨ UP(▲) / DOWN(▼) To change a menu field, use the “UP” or “DOWN” buttons. ⑩ SELECT/EDIT Use this button to change values on main menu or sub menu setting. LED Light (a) GREEN: The DVR unit is powered up and running.
Operation Manual – Art. 80153 (Version 1.1.6) ⑤ PS/2 MOUSE PORT Use this port for PS/2 mouse connection. If you have USB port mouse, use USB - PS/2 adapter to connect with this port. ⑥ SENSOR / ALARM / RS485 Sensor input You can use this sensor terminal block to install up to 4 motion sensors into DVR. If you add the motion sensor devices to your DVR, the video recording can be triggered by motion detection.
Operation Manual – Art. 80153 (Version 1.1.6) 2.5 Remote Control (optional) 1. CH1 ↑ Select or enlarge CH1 or Move dome up 2. CH2 ↓ Select or enlarge CH2 or Move dome down 3. CH3 ← Select or enlarge CH3 or Move dome left 4. CH4 → Select or enlarge CH4 or Move dome right 5.QUAD Quad View 6. ◄◄ Z- Rewind or Zoom- 7. ► F+ Play record list or Focus+ 8. ►► Z+ Forward or Zoom+ or Channel auto sequence switch 9. ● Manual recording or Stop manual recording or Reduce 10.
Operation Manual – Art. 80153 (Version 1.1.6) 4. HARDWARE SETUP 4.1 IDE Hard Disk Drive Installation NOTE: Make sure that HDD jumper setting as “MASTER” Before installing hard drive, set jumper as “MASTER”. The master jumper setting varies depending on the hard drive manufactures. Refer to manufacture’s manual for master jumper setting. For example, this model of HDD is Seagate. Connect the ribbon cable (IDE) cable & power cable Back side of hard disk 4.
Operation Manual – Art. 80153 (Version 1.1.6) 4.3 Monitor Connection To display video image from cameras on the monitor, the DVR’s video output signal should be transferred to your TV set or monitor. Connect a monitor at “VIDEO OUT” ports on DVR “VIDEO IN” port on MONITOR “VIDEO OUT” port on DVR Connect “VIDEO IN” of the monitor to “VIDEO OUT” of the DVR system. 4.4 Camera Connection Connect between “VIDEO IN” of your DVR and “VIDEO OUT” of camera with video cable and plug in the camera’s power adapter.
Operation Manual – Art. 80153 (Version 1.1.6) * Only the corresponding channel will record when a sensor trips, (e.g. sensor one corresponds with channel one). (1) Normal-Close (2) Normal-Open (3) Normal Close & Open 4.6 Alarm Connection The DVR has an internal switch for sounding alarm. The switch is normally open, but when the sensor is triggered, the alarm is activated as well. The circuitry is as follows. First, connect the alarm power lines to the alarm switch terminal.
Operation Manual – Art. 80153 (Version 1.1.6) If users install a new hard disk drive, it will ask for HDD formatting before a system starts to run (Below Fig). Choose FORMAT option pressing “PLAY” button. 5. SETUP After installing a new hard drive on the system, user had better to format the hard drive first. There are three password levels in the system that including Admin (highest), Operator, and Guest (lowest).
Operation Manual – Art. 80153 (Version 1.1.6) The Admin can operate everything, the Operator can operate everything except examining user accounts and modifying its password level and the Guest can operate live video display and image playback. After system boot-up, hold a right mouse click button and there will be login window. Hold a left mouse click button to click the order of “Account”, and input correct account. Then left click the order of “Password” and input correct password.
Operation Manual – Art. 80153 (Version 1.1.6) The DVR Front Panel or Remote Control Press the “UP” or “DOWN” key on the DVR front panel or remote control to move the cursor. Press “SELECT” button on the front panel or remote control in order to change the settings. In the MAIN MENU, the cursor “ ” will be shown on the screen right next to each sub menu. To go back to the previous, press “MENU” button on the front panel or remote control. The Mouse Control Move the mouse up or down to move the cursor.
Operation Manual – Art. 80153 (Version 1.1.6) Press button 【ENTER】or hold a left mouse click button to click icon “►” to increase the record frame rate for each channel. Press button 【REC】or hold a left mouse click button to click icon “◄” to decrease the record frame rate for each channel. If you make the record frame rate off, the channel won’t record. RECORD QUALITY Choose record quality among Normal / Low / High. The higher the record quality is, the higher the video image quality is well you playback.
Operation Manual – Art. 80153 (Version 1.1.6) 5.3 ALARM Using SELECT button or hold a left mouse button to click icon “◄” / “►” adjust parameters of each option. ALARM DURATION It sets the alarm duration time (in seconds) after alarm is activated. Value at “05, 10, 15, 20, 25, 30, CONT, OFF”(in seconds). Default is “OFF”. By changing the value in the ALARM DURATION, you can adjust how long the alarm will last in seconds. The alarm device should be installed.
Operation Manual – Art. 80153 (Version 1.1.6) MOTION AREA Use this option to select the range of motion detection area. Use the keypad button, remote control button or mouse click to assign the area. The keypad and mouse control instructions are below. Using keypad or remote control button Press [SEL] once to pitch on the area, press [SEL] twice to cancel the area. QUAD: Select or deselect the motion detection area for motion detection recording.
Operation Manual – Art. 80153 (Version 1.1.6) 5.5 AUDIO Make the record “ON” to enable sound recording when a microphone device is attached in AUDIO INPUT port on the system. Adjust volume for speaker and the intensity level of sound recording. To make the sound enabled for speaker, leave the mute “OFF”. 5.
Operation Manual – Art. 80153 (Version 1.1.6) 5.6.1 HARD DISK SETUP OVERWRITE ENABLED If you choose YES, recording continues and overwrites previous recording when hard disk drive space is full. If you choose NO, the recording stops when the hard disk drive is full. FORMAT HDD If you format the hard disk drive, all the video data stored on the hard disk drive will be deleted! Remind that the system has no restore option once the hard drive is formatted.
Operation Manual – Art. 80153 (Version 1.1.6) 5.6.2 ACCOUNT SETUP Only if the user log in the system at Admin level, the Account Setup allows the administrator to add new users, delete existing ones and modify the user’s name / password / level. The system allows up to 4 user accounts. [Account]/[Password] In setup Menu display, move the cursor to change the highlighted option to Account and then press ENTER to call up Account/Password as shown.
Operation Manual – Art. 80153 (Version 1.1.6) When password change succeed, user will see the below message blowing. When password change fail, user will see the below message blowing. 5.6.4 KEYPAD TONE Make the keypad tone “ON” or “OFF” to enable or disable keypad tone during operating. 5.6.5 TIME SET You can adjust the current time, date and year at any time by region. Set your region first and set the current time so that the video back-up data can be played without time shifting later on.
Operation Manual – Art. 80153 (Version 1.1.6) To playback by EVENT LIST, using [UP]/[DOWN] or channel number (CH1 for Page Up or CH2 for Page Down) key on the front panel or remote control, select the event that you want to playback and press “PLAY” button. Another way is to move the mouse up and down or click the left mouse button (“◄” for Page Up or “►” for Page Down), select the event that you want to playback and double click the left mouse button. Then it wills playback the recording video data. 5.6.
Operation Manual – Art. 80153 (Version 1.1.6) Mouse function: Left Mouse: Click the icon “►” or “◄” to adjust value. Right Mouse: Previous. Preset setup: User must set preset at first. The address, protocol and baud rate of DVR is consistent with Dome’s. You can make use buttons to control dome and save the preset. If user wants to call preset, user can modify the value of preset to come true. Press「Select」button to finish the order of “call preset”.
Operation Manual – Art. 80153 (Version 1.1.6) 5.6.9 USB TEST This option is testing purpose only. Users can check the compatibility of the USB memory stick for backup. 5.7 LANGUAGE Our system supports multi-language OSD. On the menu of “Language”, you can move the cursor to change it by pushing “SELECT” button on the front panel or remote control and also can move the mouse to single left-click to select the language. 5.
Operation Manual – Art. 80153 (Version 1.1.6) Mouse Control: Hold a right mouse click button and left click the icon “►”. Then press the left mouse button to change the value of the playback start date & time and press the right mouse button. Then hold a left mouse button to click “Search”, the playback will start from the date & time indicated by the user. 7.
Operation Manual – Art. 80153 (Version 1.1.6) USB copy: Move the cursor to “USB copy” and press “SELECT” button or hold a left mouse click button to back up a stream of video data on USB memory stick. It will take a few minutes to write the video data on USB memory stick. The file size number is going up until it’s done with the message below. WRITING… Then it will show the following message on the screen. FIXATING… Take out the USB memory stick and attach it into your PC when it’s done.
Operation Manual – Art. 80153 (Version 1.1.6) 9. SPECIFICATIONS ITEM DESCRIPTION Video Format NTSC / PAL Operation System None Camera Input Channel 4 channel Composite BNC Video Output Channel 1 channel Composite BNC Recording Frame Rate NTSC Max 60 fps (Total) PAL Max.50 fps (Total) NOTE STAND-ALONE Max. 30 frames/s (Each Channel) Max.
Operation Manual – Art. 80153 (Version 1.1.6) 10. APPENDIX 10.1 System connect sketch map 10.2 Fitting come along with art. 80153 Power adapter, power cord, user manual (this manual), USB drive CD. 10.3 Compatible USB stick for art. 80153 (tested).