Installation Guide

GLASS RAILINGS
G
C
ClearViewClearView
GLASS RAILINGS
G
C
TM
®
Wood Deck
Installation
We suggest using 3/8”
diameter x 4” ASTM A307
Grade A structural bolts and
flat washer
. ASTM A307
Grade A structural bolts and
washer should be cadmium
plated or stainless steel so
they do not rust. RSS Rugged
Structural Screws by GRK (see
next page) can also be used.
Lag bolts must be installed
into rim joists or lam beam or
properly blocked sub structure.
If lag bolts are attached to deck
planks only failure will occur as
a result of improper installation.
Improper installation and failure
may result in injuries or death.
Do it once and do it right!
INSTALLATION WITH
TWO OR THREE SPIGOTS
2 Spigot Installation
Will withstand wind gusts up
to 115 mph.
3 Spigot Installation
Will withstand hurricane
force winds.
Sheet
X of X
Chris Hartnett &
Associates Preservation
Engineers
521 S. 9th St. #2
Minneapolis, MN 55404
Revisions
#
date
Project #
Project:
Address:
I hereby certify that this drawing was prepared by me or
under my direct supervision and that I am a duly Licensed
Professional Engineer under the laws of the state of
Minnesota.
Chris A. Hartnett
License # 4237
1
1 of 1
CLEAR VIEW GLASS
RAILING
737 QUENTIN AVE S.
LAKELAND, MN 55403
Connection: (4) 3/8" x
4" lag bolts into (3)
2x10 boards x 10"
long.
For exterior: recommend that
bolt be galvanized or
stainless steel for durability
Spigot
GENERAL NOTES:
1. THIS GUARDRAIL SYSTEM IS IN COMPLIANCE WITH THE 2014 AND 2017
INTERNATIONAL BUILDING CODE (IBC) SECTION 1607.8. IT IS ALSO IN
ACCORDANCE WITH 2015 IBC SECTION 2407 THAT REQUIRES ALL-GLASS
HANDRAILS AND GUARDS BE "LAMINATED GLASS CONSTRUCTED OF
FULLY TEMPERED OR HEAT-TREATED GLASS".
2. CONNECTION TO DECK SHOWN (4) 3/8" LAG BOLTS THROUGH DECK TO
(3) 2X10 BOARDS, MEETS IBC DECK REQUIREMENTS FOR A 200 POUND
POINT LOAD OR 500 POUND LINE LOAD AT ANY PLACE ON PANEL.
LOADING TO BE EITHER VERTICAL OR HORIZONTAL BUT NOT
SIMULTANEOUS.
2. WHEN THREE SPIGOTS ARE USED, THIS PRODUCT COMPLIES WITH THE
REQUIREMENTS FOR HIGH VELOCITY HURRICANE ZONES (HVHZ).
3. SPIGOTS TO BE 316 STAINLESS STEEL.
4. CONNECTION TO BUILDING VARY BY PROJECT, TO BE DESIGNED BY
PROJECT ENGINEER. CONNECTION TO WOOD STAIR STRINGER IS
DESIGNBED AND SHOWN HEREIN.
5. THE ABIILITY OF THE EXISTING HOST STRUCTURE TO SAFELY
SUPPORT THE LODS SHALL BE DETERMINED BY THE PROJECT
ENGINEER.
6. MECHANICAL FASTENERS, AS SHOWN.
36" or 42"
12"
12"
36"
SPIGOT CONNECTION TO GLASS
2 3/8"
1 1/4"
1 1/2"
Connection to base
material varies.
NOTE: Panels in high wind coastal areas require
three spigot, all other areas require two.
Part Number
Product Name
Spigot Size
Spigot Weight
Glass Thickness/
Dimensions/Weight
(per panel
Accessories
Included
CVGR 316 SSOD48-180
Satin Finish
Round Deck Mount
Spigot
1.9" diameter x 7.1" tall
5.5 pounds
13.5 mm/60" wide x
39.37" tall/ 98.5 pounds
Base Cover, Rubber
Gasket
Wood stringer beyond
CVGR Spigot Attachment to Wood Deck (additional instructions)
Connection: (4) 3/8” Lag Bolts
Wood joist beyond
GENERAL NOTES:
1. IBC REQUIREMENTS 2407.1.1 (2018 IBC) REQUIRES ALL GLASS HANDRAILS AND GUARDS BE LAMINATED, FULLY TEMPERED OR HEAT TEMPERED
LIKE CLEARVIEW GLASS RAILINGS’ HERCULES GLASS.
2. CONNECTION TO DECK SHOWN (4) 3/8” LAG BOLTS THROUGH DECK TO (3) 2X10 BOARDS, MEETS IBC DECK REQUIREMENTS FOR A 200 POUND
POINT LOAD OR 50 POUND LINE LOAD AT ANY PLACE ON PANEL. LOADING TO BE EITHER VERTICAL OR HORIZONTAL BUT NOT SIMULTANEOUS.
3. WHEN THREE SPIGOTS ARE USED, THIS PRODUCT COMPLIES WITH THE REQUIREMENTS FOR HIGH VELOCITY HURRICANE ZONES (HVHZ).
4. SPIGOTS TO BE 316 STAINLESS STEEL.
5. CONNECTION TO STRUCTURE VARIES BY PROJECT AND IS TO BE DESIGNED BY THE PROJECT ENGINEER. THE ABILITY OF THE EXISTING HOST
STRUCTURE TO SAFELY SUPPORT THE LOADS SHALL BE DETERMINED BY THE PROJECT ENGINEER.
6. MECHANICAL FASTENERS, AS SHOWN.
See Page 4 for Concrete Attachment