What BAUD rate is used for the serial port transmission speed.
If you disable Console Redirection, this option is not available.
This can be one of the following:
9.6kA 9600 BAUD rate is used.
19.2kA 19200 BAUD rate is used.
38.4kA 38400 BAUD rate is used.
57.6kA 57600 BAUD rate is used.
115.2kA 115200 BAUD rate is used.
This setting must match the setting on the remote
terminal application.
Note
Baud Rate
What type of character formatting is used for console redirection.
This can be one of the following:
PC-ANSIThe PC-ANSI terminal font is used.
VT100A supported vt100 video terminal and its
character set are used.
VT100-PLUSA supported vt100-plus video terminal
and its character set are used.
VT-UTF8A video terminal with the UTF-8 character
set is used.
This setting must match the setting on the remote
terminal application.
Note
Terminal Type
What timeout value the BIOS uses to configure the watchdog
timer. This can be one of the following:
The watchdog timer expires 5 minutes after the OS
begins to boot.
The watchdog timer expires 10 minutes after the OS
begins to boot.
The watchdog timer expires 15 minutes after the OS
begins to boot.
The watchdog timer expires 20 minutes after the OS
begins to boot.
This option is only applicable if you enable the OS
Boot Watchdog Timer.
Note
OS Boot Watchdog Timer Timeout
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
OL-28893-01 233
BIOS Parameters by Server Model
Server Management BIOS Parameters for C260 Servers