PATRIOT METERING PUMP MANUAL PAT-CP-3000 & PAT-CP-3000-ADH Rev.
Patriot Metering Pump Manual PAT-CP-3000 CORPORATE HEADQUARTERS and MANUFACTURING 200A Perimeter Park Road · Knoxville, TN 37922 · USA · Tel: +1 (865) 321-8809 TECHNOLOGY CENTER and MANUFACTURING 1862 Ives Ave. * Kent, WA 98032 * Tel 253-854-2660 * Fax 253-854-1666 E-mail: info@mvpind.com · www.mvpind.com Rev.
Patriot Metering Pump Manual PAT-CP-3000 Table of Contents SECTION: Page TERMS & CONDITIONS OF SALE 4 SAFETY & WARNINGS 6 INTRODUCTION 15 PUMP DISASSEMBLY 17 PUMP REASSEMBLY 18 PARTS DRAWINGS 20 SLAVE ARM STICKERS 26 REVISION INFORMATION 28 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Terms & Conditions of Sale: GSSC, Inc.’s Terms & Conditions of Sale (“Terms & Conditions”) 588284v4 1. ACCEPTANCE: Acceptance of any purchase order from a customer or potential customer (“Buyer”) is subject to credit approval by GSSC, Inc. (“Seller”), acceptance of the purchase order by Seller and, when applicable, any manufacturer, vendor, or other third party that provides goods to Seller for resale to Buyer (“Vendor”).
Patriot Metering Pump Manual PAT-CP-3000 15. WARRANTIES: (a) SELLER’S WARRANTIES: Seller warrants that all Goods sold shall mechanically operate as specified and shall be free from faults in respect to materials and workmanship for a period of: (i) for parts, twelve (12) months from the date of invoice, and (ii) for systems, twelve (12) months from startup, or, if earlier, eighteen (18) months from the date of the bill of lading.
Patriot Metering Pump Manual PAT-CP-3000 SAFETY & WARNING INFORMATION: OPERATING YOUR POLYESTER SYSTEM SAFELY 1. Introduction Any tool, if used improperly, can be dangerous. Safety is ultimately the responsibility of those using the tool. In like manner, safe operation of polyester processes is the responsibility of those who use such processes and those who operate the equipment. This manual outlines procedures to be followed in conducting polyester operations safety.
Patriot Metering Pump Manual PAT-CP-3000 Type of Fire Extinguishing equipment recommended: Fire Extinguisher – code ABC, rating number 4a60bc. Extinguishing Media – Foam, Carbon Dioxide, Dry Chemical, Water Fog. Copies of the above bulletins are available, at a nominal charge from: National Fire Protection Association 470 Atlantic Avenue Boston, MA 02210 Research Report No.11 of the American Insurance Association deal with “Fire, Explosion and Health Hazards of Organic Peroxides”.
Patriot Metering Pump Manual PAT-CP-3000 2.2 Catalyst (Methyl Ethyl Ketone Peroxide) MEKP is among the more hazardous materials found in commercial channels. The safe handling of the “unstable (reactive)” chemicals presents a definite challenge to the plastics industry.
Patriot Metering Pump Manual PAT-CP-3000 C. Prevent contamination of MEKP with other materials, including polyester over spray and sandings, polymerization accelerators and promoters, brass, aluminum and non-stainless steels. D. Never add MEKP to anything that is hot, since explosive decomposition may result. E. Avoid contact with skin, eyes and clothing. Protective equipment should be worn at all times. During clean-up of spilled MEKP, personal safety equipment, gloves and eye protection must be worn.
Patriot Metering Pump Manual PAT-CP-3000 When all three elements are present, the result can be an extremely violent explosion. The reaction can be sustained with very little aluminum or galvanized metal; any amount of aluminum is too much. A. The reaction is unpredictable. Prior use of an HHC solvent without incident (corrosion or explosion) does NOT mean that such use is safe. These solvents can be dangerous alone (as a clean-up or flushing agent) or when used as a component or a coating material.
Patriot Metering Pump Manual PAT-CP-3000 G. Adequate ventilation (as covered in OSHA Section 1910.94 and NFPA No.91) is important wherever solvents are stored or used, to minimize, confine and exhaust the solvent vapors. H. Solvents should be handled in accordance with OSHA Section 1910.106 and 1910.107. 2.4 Catalyst Diluents Magnum Venus Products spray-up and gel-coat systems currently produced are designed so that catalyst diluents are not required.
Patriot Metering Pump Manual PAT-CP-3000 2.7 Toxicity of Chemicals A. Magnum Venus Products recommends that you consult OSHA Sections 1910.94, 1910.106, 1910.107 and NFPA No.33, Chapter 14, and NFPA No.91. B. Contact your chemical supplier(s) and determine the toxicity of the various chemicals used as well as the best methods to prevent injury, irritation and danger to personnel. C. Also determine the best methods of first aid treatment for each chemical used in your plant. 2.
Patriot Metering Pump Manual PAT-CP-3000 3.0 Equipment Safety WARNING Magnum Venus Products suggests that personal safety equipment such as EYE GOGGLES, GLOVES, EAR PROTECTION, and RESPIRATORS be worn when servicing or operating this equipment. Ear protection should be worn when operating a fiberglass chopper to protect against hearing loss since noise levels can be as high as 116 dB (decibels).
Patriot Metering Pump Manual PAT-CP-3000 3.2 Grounding Grounding an object means providing an adequate path for the flow of the electrical charge from the object to the ground. An adequate path is one that permits charge to flow from the object fast enough that it will not accumulate to the extent that a spark can be formed. It is not possible to define exactly what will be an adequate path under all conditions since it depends on many variables.
Patriot Metering Pump Manual PAT-CP-3000 Introduction: This manual, the Patriot Metering Pump Manual PAT-CP-3000, provides information you need to perform simple maintenance and repair on your equipment. Step-by-step assembly and disassembly procedures are included for each component. Please read the manual carefully. Follow the steps in the order given, otherwise you may damage the equipment or injure yourself.
Patriot Metering Pump Manual PAT-CP-3000 Removing metering pump from system: 1. Place clean 5-gallon pail under the metering pump to collect any potential spills. 2. Close the main air supply ball valve to system. 3. Open catalyst / material manifold ball valve to release fluid pressure. 4. Use a 5/64” Allen wrench to release catalyst accumulator charge (see resin and catalyst accumulator charging procedures in operations manual). 5. Remove the catalyst / hardener feed tube from the Inlet fitting.
Patriot Metering Pump Manual PAT-CP-3000 Pump Disassembly: Warning: Never use any type of grease or lubricants on metering pump or fittings. Clean parts in distilled water or appropriate solvent if using a hardener other then catalyst. Lay parts on clean paper towels that will be reused. Note: Do not remove Fitting body (PAT-CP-0505) from Outlet body. It is also recommended the catalyst jug and screens are cleaned using distilled water.
Patriot Metering Pump Manual PAT-CP-3000 Pump Assembly: Seal kit part # PAT-CP-3000 PAT-CP-3000-ADH-SK Reassembly of metering pump: 1. Install Rod Seals (PAT-CP-3001) and Leak Spacer (PAT-CP-3007) into the Outlet Body (PAT-CP-3003) in the following order. Rod Seal (O-ring facing down) then Leak Spacer, then second Rod Seal (O-ring facing down). Push the stack down into the Outlet Body. Install Retaining Nut only hand tight. 2. Install Spring (04009-1) into the end of the Fluid Rod (PAT-CP-3008).
Patriot Metering Pump Manual PAT-CP-3000 8. Install Ball (9201-1-14) and Ball Cage (PAT-CP-3009) into Inlet Body (PAT-CP3002). 9. Screw Outlet Body (PAT-CP-3003) into Inlet Body (PAT-CP-3002) until it bottoms out. If the inlet and outlet hose fittings are not in proper position to attach to metering pump drive, back the outlet body out before bring the lock nut down and tightening against the inlet body. If not sure, complete assembly and attach to drive before tightening the lock nut. 10.
Patriot Metering Pump Manual PAT-CP-3000 Parts Drawings: PAT-CP-3000 PAT-CP-3000-ADH PAT-CP-3000-SK PAT-CP-3000-ADH-SK METERING PUMP ASSEMBLY METERING PUMP ASSEMBLY – ADHESIVE METERING PUMP SEAL KIT METERING PUMP SEAL KIT – ADHESIVE Rev.
Patriot Metering Pump Manual PAT-CP-3000 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Rev.
Patriot Metering Pump Manual PAT-CP-3000 Slave Arm Sticker: PAT-CP-3000 METERING PUMP AND PAT-LS-49090 FLUID SECTION PAT-CP-3000 METERING PUMP AND PAT-LS-24050 FLUID SECTION PAT-CP-3000 METERING PUMP AND PAT-LS-12270 FLUID SECTION PAT-CP-3000 METERING PUMP AND PAT-CCP-LS-0590 FLUID SECTION PAT-CP-3000 METERING PUMP AND PAT-CCP-LS-0590 FLUID SECTION Rev.
Patriot Metering Pump Manual PAT-CP-3000 Revision Information: Revision: Description: Rev: 04/2013 Created this manual Rev. 08/2013 Updated the “Terms & Conditions” section and the drawings. Added the Slave Arm stickers to their section. Rev: 07/2014 Updated the drawings. Updated the Logo and Name. Removed references to Plastech. Rev.
Patriot Metering Pump Manual PAT-CP-3000 CORPORATE HEADQUARTERS and MANUFACTURING 200A Perimeter Park Road · Knoxville, TN 37922 · USA · Tel: +1 (865) 321-8809 TECHNOLOGY CENTER and MANUFACTURING 1862 Ives Ave. * Kent, WA 98032 * Tel 253-854-2660 * Fax 253-854-1666 E-mail: info@mvpind.com · www.mvpind.com www.mvpind.com Assemblies Covered in this Manual: PAT-CP-3000 Catalyst Pump Assembly PAT-CP-3000-ADH Metering Pump Assembly – Adhesive Systems Rev.