Owner's manual
Table Of Contents
- 1: E-F-S Cover
- 2: Eng - 1
- 3: Eng - 2
- 4: Eng - 3
- 5: Eng - 4
- 6: Eng - 5
- 7: LI INSERT ENG
- Page 8
- Page 9
- 10: WARRANTY ENG
- 11: Fre-P1
- Page 12
- Page 13
- Page 14
- Page 15
- Page 16
- Page 17
- Page 18
- Page 19
- 20: Spa - 1
- 21: Spa - 2
- 22: Spa - 3
- 23: Spa - 4
- 24: Spa - 5
- 25: LI INSERT SPA
- Page 26
- Page 27
- 28: WARRANTY SPA
- 29: ASSEMBLY START
- Page 30
- Page 31
- Page 32
- Page 33
- Page 34
- Page 35
- Page 36
- Page 37
- Page 38
- Page 39
- 40: GG_Eng
- Page 41
- Page 42
- Page 43
- 44: GG_Fre
- Page 45
- Page 46
- Page 47
- 48: GG_Spa
- Page 49
- Page 50
- Page 51
- 52: TS ENG
- Page 53
- 54: TS_FRE
- Page 55
- 56: TS SPA
- Page 57
- 58: Parts Diagram
- 59: Parts List Eng
- 60: PL_FRE
- 61: Parts List Spanish
- 62: Hardware
- 63: REGISTRATION PAGE
- 64: BACK COVER
52
EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Emergencies
Problem
Gas leaking from
cracked/cut/burned hose.
Gas leaking from LP cylinder.
Gas leaking from LP
cylinder valve.
Gas leaking between LP
cylinder and regulator
connection.
Fire coming through control
panel.
Grease fire or continuous
excessive flames above
cooking surface.
Burner(s) will not light
using ignitor.
(See Electronic Ignition
Troubleshooting also)
Continued on next page.
Possible Cause
Possible Cause
• Damaged hose.
• Mechanical failure due to rusting or mishandling.
• Failure of cylinder valve from mishandling or
mechanical failure.
• Fire in burner tube section of burner due to blockage.
• Too much grease buildup in burner area.
GAS ISSUES:
• Trying to light wrong burner.
• Burner not engaged with control valve.
• Obstruction in burner.
• No gas flow.
• Coupling nut and LP cylinder valve not fully
connected.
ELECTRICAL ISSUES:
• Electrode cracked or broken; “sparks at crack.”
• Electrode tip not in proper position.
(Does not apply to SUREFIRE.)
• Wire and/or electrode covered with cooking residue.
• Wires are loose or disconnected.
• Wires are shorting (sparking) between ignitor and
electrode.
• Dead battery.
Prevention/Solution
Prevention/Solution
• Replace LP cylinder.
• Turn off LP cylinder valve. Return LP cylinder to gas supplier.
• Turn off control knobs and LP cylinder valve. Leave lid open to allow flames to die
down. After fire is out and grill is cold, remove burner and inspect for spider nests or
rust. See Natural Hazard and Cleaning the Burner Assembly pages.
• Turn off control knobs and LP cylinder valve. Leave lid open to allow flames to die
down. After cooling, clean food particles and excess grease from inside firebox area,
grease tray, and other surfaces.
• See instructions on control panel and in Use and Care section.
• Make sure valves are positioned inside of burner tubes.
• Ensure burner tubes are not obstructed with spider webs or other matter. See
cleaning section of Use and Care.
• Make sure LP cylinder is not empty. If LP cylinder is not empty, refer to
“Sudden drop in gas flow.”
• Turn the coupling nut approximately one-half to three-quarters additional turn until
solid stop. Tighten by hand only - do not use tools.
• Replace electrode(s).
Main Burners:
• Tip of electrode should be pointing toward gas port opening on burner. The
distance should be 1/8” to 1/4”. Adjust if necessary.
Sideburner:
• Tip of electrode should be pointing toward gas port opening on burner. the
distance should be 1/8” to 3/16”. Adjust if necessary.
• Clean wire and/or electrode with rubbing alcohol and clean swab.
• Reconnect wires or replace electrode/wire assembly.
• Replace ignitor wire/electrode assembly.
• Replace with a new alkaline battery.
Troubleshooting
Burner(s) will not match light.
ELECTRONIC IGNITION:
• No spark, no ignition noise.
• No spark, some ignition noise.
• Sparks, but not at electrode or at full strength.
• See “GAS ISSUES:” .
• Match will not reach.
• Improper method of match-lighting.
• See Section I of Electronic Ignition System.
• See Section II of Electronic Ignition System.
• See Section III of Electronic Ignition System.
• Use long-stem match (fireplace match).
• See “Match-Lighting” section of Use and Care.
•Turn off gas at LP cylinder or at source on natural gas systems. Discontinue use of
product and replace valve/hose/regulator. Once valve/hose/regulator replaced
conduct complete leak check per manual.
• Improper installation, connection not tight, and/or
failure of rubber seal in clyinder valve.
•Turn off LP cylinder valve. Remove regulator from cylinder and visually inspect rubber
seal in cylinder valve for damage. If damage or cannot correct leak replace cylinder.
See LP Cylinder Leak Test and Connecting Regulator to the LP Cylinder.